VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 SHUTTLE COUNTDOWN (LPS) MAT COPY DRAFT COPY ---------- RECIPIENT(S) SHALL REVIEW THIS COPY AND SUBMIT INPUT TO: SFOC OMD:____________________ RM:________ EXT:________ DATE:________ PRELIMINARY REVIEW COPY ----------------------- RECIPIENTS SHALL REVIEW THIS COPY, COORDINATE INPUT WITH CUSTOMER COUNTERPARTS AND BRING MARKED UP COPY OF JOINT FUNCTIONAL INPUT TO THE REVIEW MEETING SCHEDULED FOR: DATE:__________ TIME:__________ RM:__________ FINAL REVIEW SIGNOFF COPY ------------------------- RECIPIENTS SHALL REVIEW THIS COPY, COORDINATE INPUT WITH CUSTOMER COUNTERPARTS AND BRING MARKED UP COPY OF JOINT FUNCTIONAL INPUT TO SIGNOFF REVIEW MEETING SCHEDULED FOR: DATE:__________ TIME:__________ RM:__________ PAGE BREAK COPY --------------- RECIPIENT(S) SHALL REVIEW THIS COPY AND SUBMIT INPUT TO: SFOC OMD:____________________ RM:________ EXT:________ DATE:________ NOTE IN EVENT OF A DISCREPANCY, THE PUBLISHED OMI REVIEW MEETING SCHEDULE TAKES PRECEDENCE OVER THIS SCHEDULE. OMI TECHNICAL CONTACT: ROGER GILLETTE, 1-7437 | OMI WRITER: PAM STIELER, 1-4958 DISTRIBUTION PER ATTACHED DISTRIBUTION LIST ------------------------------------------------------------------ THIS PROCEDURE CONTAINS HAZARDOUS OPERATIONS ------------------------------------------------------------------ VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 UNITED SPACE ALLIANCE ******************************************************** * * * SHUTTLE COUNTDOWN - (LPS) * * * ******************************************************** * EFFECTIVITY CATEGORY: A * * HA-SVTBAMQDGCWZF * * +ER * * CENTER: KSC * * SYSTEM: TCO * * SITE: PAD A/B * * * * VEHICLE: OV-102,103,104,105 * * * * FLOW: ALL * * * * DESIGN CENTER CONCURRENCE: JSC & MSFC * ******************************************************** PREPARED BY: _________________________________ SFOC TEST DOCUMENTATION APPROVED BY: CONTRACTOR _________________________________ SFOC SAFETY ENGINEERING ------------------------------------------------------------------ THIS PROCEDURE CONTAINS HAZARDOUS OPERATIONS ------------------------------------------------------------------ VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 ******************************************************** * * * SHUTTLE COUNTDOWN - (LPS) * * * ******************************************************** * EFFECTIVITY CATEGORY: A * * HA-SVTBAMQDGCWZF * * +ER * * CENTER: KSC * * SYSTEM: TCO * * SITE: PAD A/B * * * * VEHICLE: OV-102,103,104,105 * * * * FLOW: ALL * * * * DESIGN CENTER CONCURRENCE: JSC & MSFC * ******************************************************** VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 UNITED SPACE ALLIANCE ******************************************************** * * * SHUTTLE COUNTDOWN - (LPS) * * * ******************************************************** * EFFECTIVITY CATEGORY: A * * HA-SVTBAMQDGCWZF * * +ER * * CENTER: KSC * * SYSTEM: TCO * * SITE: PAD A/B * * * * VEHICLE: OV-102,103,104,105 * * * * FLOW: ALL * * * * DESIGN CENTER CONCURRENCE: JSC & MSFC * ******************************************************** PREPARED BY: _________________________________ SFOC TEST DOCUMENTATION APPROVED BY: CONTRACTOR GOVERNMENT _________________________________ ___________________________ ORBITER TEST DIRECTOR NASA TEST DIRECTOR _________________________________ SFOC SAFETY ENGINEERING ------------------------------------------------------------------ THIS PROCEDURE CONTAINS HAZARDOUS OPERATIONS ------------------------------------------------------------------ VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 REVISION RECORD PAGE -------------------- REV-CHANGE DATE REASON PAGES AFFECTED EFFECTIVITY --------------------------------------------------------------------- W : 03-14-98 : 70/USK217: ALL : ALL --------------------------------------------------------------------- W-1 : 05-16-98 : 71/USK023: 69,70,115-118,233, : ALL : : : 234,251,252,259,260, : : : : 351,352,911-920,925, : : : : 926,935,936,947,948, : : : : 953,954,1199,1200, : : : : 1275,1276,1331,1332, : : : : 1351,1352,1431-1434, : : : : 1467,1468 : --------------------------------------------------------------------- X : 10-08-98 : 72/USK217: ALL : ALL --------------------------------------------------------------------- Y : 11-19-98 : 73/USK217: ALL : ALL : : RCN : : : : MB13421 : : --------------------------------------------------------------------- Z : 05-06-99 : 74/USK206: ALL : STS-96&SUBS : : 75/USK217: : ---------------------------------------------------------------------| Z-1 : 07-01-99 : 76/USK217: 151,152,173,191,243, : STS-93&SUBS| : : : 243.1,243.2,260,284, : | : : : 297,301-303,837,839, : | : : : 840,847,975,978,1222,: | : : : 1298,1417,1418,1426, : | : : : 1429,1492-1495,1503, : | : : : 1504,1524,1563,1564 : | --------------------------------------------------------------------- VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 BACKUP SIGNATURE SHEET OMI TITLE: SHUTTLE COUNTDOWN (LPS) AGENCY SIGNATURES SYSTEM CONTRACTOR/NASA CONTRACTOR GOVERNMENT ------ --------------- ---------- ---------- SUPPORT ------- TSMO SFOC ___________________ NA TIMING/ COUNTDOWN CSR ___________________ NA RPS GTSI /NASA ___________________ _______________ CCMS/LPS GTSI /NASA ___________________ _______________ ETR PAA/SRO ___________________ NA MEASUREMENTS GTSI /NASA ___________________ _______________ PHOTO TGS ___________________ NA MILA BFEC/GUSB ___________________ NA VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 BACKUP SIGNATURE SHEET OMI TITLE: SHUTTLE COUNTDOWN (LPS) AGENCY SIGNATURES SYSTEM CONTRACTOR/NASA CONTRACTOR GOVERNMENT ------ --------------- ---------- ------------ PAYLOAD ------- TEST COND/ DIRECTOR CONTR/NASA (ROR) ___________________ _______________ SAFETY CONTR ___________________ NA MIDDECK EXP CS-EED-1 NA _______________ VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 BACKUP SIGNATURE SHEET OMI TITLE: SHUTTLE COUNTDOWN (LPS) AGENCY SIGNATURES SYSTEM CONTRACTOR/NASA CONTRACTOR GOVERNMENT ------ --------------- ---------- ---------- ORBITER ------- NAVAIDS SFOC/NASA ___________________ ________________ COMM SFOC/NASA ___________________ ________________ INSTR SFOC/NASA ___________________ ________________ HGDS SFOC/NASA ___________________ ________________ PVD SFOC/NASA ___________________ ________________ LAUNCH ACC SFOC/NASA ___________________ ________________ EPD&C SFOC/NASA ___________________ ________________ DPS SFOC/NASA ___________________ ________________ DPSME SFOC/NASA ___________________ ________________ QE SFOC ___________________ NA SAFETY SFOC ___________________ NA MPS SFOC/NASA ___________________ ________________ SSME SFOC/NASA ___________________ ________________ SSME ROCKETDYNE ___________________ NA APU SFOC/NASA ___________________ ________________ HYDRAULICS SFOC/NASA ___________________ ________________ VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 BACKUP SIGNATURE SHEET OMI TITLE: SHUTTLE COUNTDOWN (LPS) AGENCY SIGNATURES SYSTEM CONTRACTOR/NASA CONTRACTOR GOVERNMENT ------ --------------- ---------- ---------- ORBITER (CONT) -------------- PRSD SFOC/NASA ___________________ ________________ MECH/STRUC SFOC/NASA ___________________ ________________ OMS/RCS SFOC/NASA ___________________ ________________ ECLSS SFOC/NASA ___________________ ________________ TPE/PEO SFOC/NASA ___________________ ________________ VITT NASA/JSC NA _______________ JSC RESIDENT OFFICE NASA/JSC NA _______________ TPS SFOC/NASA ___________________ ________________ FCS SFOC/NASA ___________________ ________________ G&N SFOC/NASA ___________________ ________________ FLT CNTLS SFOC/NASA ___________________ ________________ ORB SOFTWARE SFOC/NASA ___________________ ________________ JSC MISSION INTEGRATION RI-LSS/JSC-TA ___________________ _______________ VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 BACKUP SIGNATURE SHEET OMI TITLE: SHUTTLE COUNTDOWN (LPS) AGENCY SIGNATURES SYSTEM CONTRACTOR/NASA CONTRACTOR GOVERNMENT ------ --------------- ---------- ---------- ET/SRB ------ TEST COND SFOC (ROR) ___________________ NA PROJ ENGR SFOC/NASA ___________________ ________________ EPD&C SFOC/NASA ___________________ ________________ INSTR SFOC/NASA ___________________ ________________ MECH (ET) SFOC/NASA ___________________ ________________ STRUC SFOC/NASA ___________________ ________________ ORDNANCE SFOC/NASA ___________________ ________________ PNEUMATICS SFOC/NASA ___________________ ________________ TPS SFOC/NASA ___________________ ________________ PROPELLANTS/ LO2 SFOC/NASA ___________________ ________________ PROPELLANTS/ LH2 SFOC/NASA ___________________ ________________ MECH (SRB) SFOC/NASA ___________________ ________________ SRSS SFOC/NASA ___________________ ________________ FLT CNTLS SFOC/NASA ___________________ ________________ DPS SFOC/NASA ___________________ ________________ HYD SFOC/NASA ___________________ ________________ VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 BACKUP SIGNATURE SHEET OMI TITLE: SHUTTLE COUNTDOWN (LPS) AGENCY SIGNATURES SYSTEM CONTRACTOR/NASA CONTRACTOR NASA ------ --------------- ---------- ------------ PAYLOAD ------- __________ _______________ ___________________ _______________ TEST CONDUCTOR MDSSC ___________________ NA P/L INTEG ENGR MDSSC/CS-PPD-1 ___________________ _______________ ELECT INTEG MDSSC/CS-PPD-32 ___________________ NA SOFTWARE MDSSC/SC-PPD-33 ___________________ NA IUS BAO/6555TH ___________________ _______________ MIDDECK EXP CS-EED-1 NA _______________ ULS ESA ___________________ NA VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 DESIGN CENTER CONCURRENCE BACKUP SIGNATURE SHEET ------------------------- OMI TITLE: SHUTTLE COUNTDOWN (LPS) AGENCY SIGNATURES SYSTEM CONTRACTOR/NASA CONTRACTOR* NASA ------ --------------- ----------- ------------ ORBITER RI LSS LEVEL III ___________________ NA ORBITER JSC LEVEL III NA _______________ ET MMC LSS ___________________ NA ET MSFC LEVEL III NA _______________ SRB USBI LSS ___________________ NA SRB MSFC LEVEL III NA _______________ SSME ROCKETDYNE LSS ___________________ NA SSME MSFC LEVEL III NA _______________ NSTS CARGO ENGR INTEG RI LSS LEVEL II ___________________ NA NSTS INTEG OPS CARGO LEVEL II NA _______________ NSTS ENGR INTEG JSC LEVEL II NA _______________ VITT TP-TMS-A NA _______________ JSC MISSION INTEGRATION RI-LSS/JSC-TA ___________________ _______________ VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 TABLE OF CONTENTS ----------------- PAGE ---- COVER PAGE APPROVAL PAGE/CHANGE RECORD PAGE TABLE OF CONTENTS OBJECTIVE/DESCRIPTION ..................................... NA ILLUSTRATIONS ............................................. NA HAZARDOUS MANLOADING ...................................... NA BAR CHARTS ................................................ NA SECTION I - INFORMATION 1.1 REFERENCED INSTRUCTIONS........................... 1 1.2 COMPUTER SYSTEMS ................................. NA 1.3 SPECIAL TOOLS, EQUIPMENT AND MATERIALS ........... NA 1.4 SUPPORT TOOLS, EQUIPMENT AND MATERIALS ........... NA 1.5 PERSONNEL REQUIREMENTS............................ 5 1.6 SAFETY REQUIREMENTS .............................. NA 1.7 SPECIAL INSTRUCTIONS ............................ NA 1.8 OMRS REQUIREMENTS SATISFIED BY THIS TOP........... 6 SECTION II - PRE-OPERATION SETUP INSTRUCTIONS NA SECTION III - OPERATION SUPPORT SETUP INSTRUCTIONS NA SECTION IV - OPERATION INSTRUCTIONS 98-000 PREPLANNED CONTINGENCY PROCEDURES............ 9 98-001 ECS/PVD...................................... 9 98-002 VENT DOOR OVERRIDE OPERATION (CONTINGENCY).... 9 98-015 ORBITER VENT DOOR INDICATOR ANOMALY PREPLANNED CONTINGENCY PROCEDURE (CPVD).................. 13 98-025 OPTION A - VENT DOOR OPEN INDICATOR ON SHOULD BE OFF........................................ 20 98-036 OPTION C - VENT DOOR PURGE INDICATOR ON SHOULD BE OFF........................................ 28 98-044 OPTION D - VENT DOOR PURGE INDICATOR OFF SHOULD BE ON.................................. 32 98-049 OPTION E - VENT DOOR CLOSE INDICATOR OFF SHOULD BE ON.................................. 35 98-055 OPTION F - VENT DOOR CLOSE INDICATOR OFF SHOULD BE ON.................................. 39 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 99-000 EPD (GSE).................................... 43 99-001 GROUND PIC PREMATURE ARM FAILURE.............. 43 99-014 LAUNCH RELEASE PIC FIRE 1 ANOMALY (REF SSID GSE-25)...................................... 48 100-000 LACC (GSE).................................... 53 100-001 OAA ACCUMULATOR RECHARGE FAILURE (LCC GSE-11) 53 100-004 OAA/GVA ARM POSITION VERIFICATION............ 54 100-006 OAA RETRACT RECONFIGURATION.................. 54 100-007 OAA LPS EXTEND/RETRACT........................ 54 100-008 OAA 2700 PSIG GN2 ADJUSTMENT.................. 54 100-009 SOUND SUPPRESSION SOLENOID POWER BUS FAILURE.. 54 100-012 SOUND SUPPRESSION FR CMD BUS FAILURE.......... 56 101-000 BUHGDS REMOTE PMSC RESET AFTER TERMINAL KEYBOARD LOCKUP.............................. 57 101-012 HGDS TO BUHGDS SWITCH OVER AND RECOVERY CONTINGENCY.................................. 61 102-000 ET............................................ 67 102-001 ET LO2/LH2.................................... 67 102-002 ET NOSECONE PURGE TEMPERATURE (SWITCH TO HEATER OUTPUT CONTROL) (CIF) (REF LCC ET-01) (T-6 HR THRU T-1M15S)........................ 68 102-003 ET NOSECONE PURGE TERMINATION (CIF) (REF LCC ET-02) (T-1M15S).............................. 69 102-004 ET LO2 HELIUM INJECT TERMINATION (CIF) (REF LCC ET-03) (T-4M20S).......................... 70 102-005 ET LH2 ULLAGE PRESSURE SWITCHOUT (CIF) (REF LCC ET-05).................................... 71 102-006 ET LO2 ULLAGE PRESSURE FAILURE (CIF) (REF LCC ET-06)........................................ 72 102-007 ET LO2 FLIGHT LEVEL MONITOR (CIF) (REF LCC ET-10) (T-19M THRU T-5M)...................... 73 102-008 ET LO2 DRAINBACK (CIF) (REF LCC MPS-09) (T-4M55S TO T-48S)............................ 74 102-009 ET INTERTANK TEMPERATURE (T-1 HOUR TO T-3 MIN) (ET-07)...................................... 75 102-010 ET INTERTANK PURGE TERMINATION (T-1 MIN 15 SEC) (ET-08).................................. 76 102-011 ET LH2 FLIGHT LEVEL MONITOR (T-1 MIN 57 SEC) (ET-09)...................................... 77 102-012 ET LH2 FILL LINE DRAIN (T-1 MIN 38 SEC TO T-48 SEC) (MPS-06)................................ 78 102-013 EXCESSIVE H2 CONCENTRATION IN LH2 TSM (FROM START OF LH2 LOADING TO T-1 MIN 57 SEC) (HAZ-10)...................................... 79 102-014 T-0 UMBILICAL EXCESSIVE H2 CONCENTRATION AT 8 IN. FEEDLINE TORQUE BOX (FROM START OF LH2 LOADING TO T-1 MIN 57 SEC) (HAZ-11).......... 80 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 102-015 EXCESSIVE H2 CONCENTRATION AT ET GROUND UMBILICAL (FROM START OF LH2 LOADING TO T-1 MIN 57 SEC) (HAZ-09).......................... 81 102-016 BIPOD HEATER TO ALTERNATE POWER.............. 82 103-000 SRB.......................................... 95 103-096 SRB RECOVERY SYSTEM PIC CAP VOLTAGE ANOMALY SSID:BREC-02.................................. 135 103-100 SRB IGNITION S & A CONTINGENCY PROCEDURE...... 136 104-000 MPS.......................................... 141 105-000 SSME.......................................... 143 105-001 SSME FUEL SYSTEM PURGE CONTINGENCY............ 143 105-006 SSME MOV/MFV HYDRAULIC TEMPERATURE CONTINGENCY 144 105-012 SSME LPOT DISCHARGE PRESSURE CONTINGENCY...... 145 105-024 SSMEC RE-INITIALIZATION OF ENGINE READY MONITORING AND FAILURE ID PARAMETER.......... 148 105-031 SSME ANTIFLOOD VALVE DOWNSTREAM SKIN TEMP CONTINGENCY (REF LCC SSME-04)................ 151 105-040 SSME HPOTP IMSL PURGE ANOMALY CONTINGENCY (REF LCC SSME-10).................................. 155 106-000 PRSD/FUEL CELL................................ 159 106-001 PROBLEM: O2 TANK PRESS OR HTR CNTL PRESS LOW (SSID PRSD-01)................................ 160 106-002 PROBLEM: O2 TANK PRESS OR HTR CNTL PRESS HIGH (SSID PRSD-01)................................ 162 106-003 PROBLEM: O2 OR H2 MANIF ISO VLV INDICATES CLOSED (SSID PRSD-02)........................ 164 106-004 PROBLEM: FCP REACT VLV INDICATES CLOSED (SSID PRSD-03)...................................... 165 106-005 PROBLEM: ONE O2 HTR CURRENT TRIP SNSR ON (SSID PRSD-04)...................................... 167 106-006 PROBLEM: T-0 VLV INDICATES OPEN (SSID PRSD-05) 169 106-007 PROBLEM: H2 TANK PRESS OR HTR CNTL PRESS LOW (SSID PRSD-06)................................ 170 106-008 PROBLEM: H2 TANK PRESS OR HTR CNTL PRESS HIGH (SSID PRSD-06)................................ 172 106-009 PROBLEM: O2 TANK QUANTITY LOW, H2 TANK QUANTITY LOW (SSID PRSD-07/08)................ 174 106-010 PROBLEM: O2 ECS VLV INDICATES CLOSED (SSID PRSD-09)...................................... 175 106-011 PROBLEM: FCP VOLTS LOW (SSID FCP-01.......... 176 106-012 PROBLEM: FCP CURRENT LOW (SSID FCP-01)........ 177 106-013 PROBLEM: FCP TEMPS (STACK IN, STACK OUT, CONDENSER EXIT) HIGH OR LOW (SSID FCP-02).... 178 106-014 PROBLEM: SUBSTACK DELTA V NEAR 50 MV OR NEAR 0 MV (SSID FCP-03).............................. 179 106-015 PROBLEM: SUBSTACK DELTA V > 28MV CHANGE DURING LOAD ADJUST (SSID FCP-03).................... 180 106-016 PROBLEM: SUBSTACK DELTA V > 18 MV CHANGE AT STEADY STATE LOADS (SSID FCP-03).............. 181 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 106-017 PROBLEM: FCP COOLANT PRESS LOW/HIGH (SSID FCP-04)...................................... 182 106-018 PROBLEM: FCP COOLANT PUMP INDICATES OFF (SSID FCP-04)...................................... 183 106-019 PROBLEM: H2 PUMP MOTOR CONDITION HIGH OR LOW (SSID FCP-04)................................ 184 106-020 PROBLEM: PH SNSR ON > 5 MINUTES (SSID FCP-05) 185 106-021 FUEL CELL WATER PH SENSOR TEST AT GALLEY...... 186 106-039 PROBLEM: RLF NOZZLE TEMP HIGH OR LOW (A OR B) (SSID FCP-05)................................ 191 106-040 PROBLEM: RLF VLV TEMPS, RLF LINE TEMPS, ALT LINE TEMPS LOW (SSID FCP-06).................. 192 107-000 OMS/RCS...................................... 193 107-001 RCS THRUST INJECTOR TEMPERATURE ANOMALY (RCS-06)...................................... 194 107-002 RCS THRUST INJECTOR TEMPERATURE ANOMALY (RCS-06) (CONT'D)............................ 195 107-003 RCS THRUST INJECTOR TEMPERATURE ANOMALY (RCS-06) (CONT'D)............................ 196 107-004 RCS THRUST CHAMBER PRESSURE (RCS-08).......... 197 107-005 RCS CHAMBER PRESSURE INDICATION ANOMALY...... 197 107-006 LEFT OMS CROSSFEED B VALVE ANOMALY (OMS 07).. 197 107-007 LOMS CROSSFEED B OXID OR FUEL VALVE PRESENCE OF OPEN VP1 OPTION............................ 198 107-016 LOMS CROSSFEED B OXID OR FUEL VALVE LACK OF CLOSED VP1 OPTION............................ 201 107-018 OMS GN2 ARM VALVE ANOMALY (OMS 10)............ 203 107-020 OMS GN2 ARM VALVE ANOMALY (OMS 10) COMPLETE.. 203 108-000 APU.......................................... 205 109-000 HYD.......................................... 247 109-001 LCC HY10 WSB OK ANOMALY...................... 247 109-002 WSB "OK" AFTER T-30M N2 VALVE ACTIVATION...... 247 110-000 ECLSS........................................ 249 110-001 CABIN VENT.................................... 249 110-002 DUMP POTABLE WATER THRU THE OVERBOARD BLEED VALVE........................................ 249 110-003 VENT GN2 FROM THE GAS SIDE OF THE POTABLE WATER TANKS.................................. 249 110-004 CONFIRM HEATER STRING FAILURE................ 249 110-005 RECONFIGURE FES CONTROLLER.................... 249 110-006 TRANSFER GCU SUPPORT TO BACKUP................ 249 110-007 LOSS OF ALL THREE SETS OF S70-0509/0510 REFR UNITS........................................ 250 110-008 S70-0510 RESTART (510 AMPERAGE LESS THAN 2.... 251 110-009 S70-0509 RESTART (UNIT OFF).................. 252 110-010 S70-0509 PROBLEM INDICATION RESET (FOR INFO ONLY AFTER T-6 HOURS)........................ 253 110-011 S70-1203 CRITICAL FAULT...................... 254 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 110-012 S70-1203 PROBLEM INDICATION.................. 255 110-013 GCU HARDWIRE SAFING PANEL OPERATION (REFRIGERATION OPERATIONS ONLY).............. 255 111-000 DPS/BFS...................................... 257 111-001 1. PASS MCDS ANOMALY RECOVERY................ 258 111-011 2. GPC I-FAIL CONTINGENCY (CIF).............. 262 111-018 3. G1 FC MDM BYPASS RECOVERY.................. 264 111-036 4. G9 MDM BYPASS RECOVERY.................... 268 111-051 6. BFS I/O ERROR PCM RECOVERY................ 272 111-066 7. MMU2 POSITION TAPE ERROR RECOVERY.......... 277 111-088 8. BFS PL MDM BYPASS RECOVERY................ 280 111-106 9. BFS MCDS ANOMALY RECOVERY.................. 283 111-117 10. DDU GOOD FAILURE RECOVERY (CIF).......... 286 111-139 11. DDU POWER SUPPLY A, B, OR C ANOMALY (CIF) 294 111-152 12. G9 QUICK RECYCLE.......................... 297 111-193 13. REMOTE BFS DEACTIVATION.................. 305 112-000 COMM AND TRACK................................ 311 112-001 TACAN POWER STATUS PREPLANNED PROCEDURE (CT-01)...................................... 311 112-002 TACAN BLANKING - TEST PREPLANNED PROCEDURE.... 313 112-003 TACAN BLANKING - TEST PREPLANNED PROCEDURE.... 315 112-004 TACAN BLANKING - TEST PREPLANNED PROCEDURE.... 316 112-005 TACAN AGC (INTERFERENCE) PREPLANNED PROCEDURE 317 112-006 TACAN AGC (INTERFERENCE) PREPLANNED PROCEDURE 318 112-007 TACAN AGC (INTERFERENCE) PREPLANNED PROCEDURE 319 112-008 RADAR ALTIMETER READY STATUS PREPLANNED PROCEDURE (CT-08)............................ 320 112-009 TACAN VALIDITY PREPLANNED PROCEDURE.......... 322 112-010 TACAN RECONFIGURE FOR A PRESSURE DROP........ 326 112-011 LCC PROCEDURE - AGC LOSS...................... 327 112-012 LCC PROCEDURE - AGC PARTIAL LOSS.............. 328 112-013 LCC PROCEDURE - GCIL INACTIVE................ 329 112-014 LCC PROCEDURE - NSP FRAME SYNC LOSS.......... 330 112-015 LCC PROCEDURE - PA POWER OUTPUT LOSS.......... 331 112-016 LCC SUB PROCEDURE - MILA OUTPUT VERIFY........ 332 112-017 COMM LCC SUB PROCEDURE - FRAME SYNC LOSS COMPARE...................................... 333 112-018 COMM LCC SUB PROCEDURE - CHECKOUT COMMANDS.... 334 112-019 COMM LCC SUB PROCEDURE - CMD TO STRING 2...... 335 112-020 S-BAND/UHF UPLINK/DOWNLINK NETWORK............ 336 112-021 A/G ORBITER DOWNLINK NETWORK.................. 337 112-022 A/G ORBITER UPLINK NETWORK.................... 338 112-023 A/G BACKUP LANDLINES AND ALTERNATE VOICE PATHS 339 112-024 LCC PROCEDURE - NSP BITE FAILURE.............. 340 112-025 LCC PROCEDURE - A/G1 LOSS.................... 341 112-026 LCC SUB-PROCEDURE - KSC A/G1 PROBLEM.......... 343 112-027 LCC SUB-PROCEDURE - KSC/MILA AG1 PROBLEM...... 346 112-028 LCC PROCEDURE - MILA/JSC/GSFC AG1 PROBLEM.... 348 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 112-029 LCC PROCEDURE - ORBITER AG1 PROBLEM.......... 349 112-030 LCC PROCEDURE - FIXED AG1 LINK................ 350 112-031 CDR PLT OR MS2 VOICE FAILURE.................. 351 112-032 COMM LCC CONTINGENCY PROCEDURES.............. 353 112-033 COMM SUB PROCEDURES - MILA OUTPUT VERIFY...... 353 112-038 AGC TOTAL LOSS CONTINGENCY.................... 356 112-042 AGC PARTIAL LOSS CONTINGENCY.................. 357 112-073 GCIL INACTIVE CONTINGENCY.................... 365 112-128 FRAME SYNC LOSS CONTINGENCY.................. 381 112-151 UHF A/A VOICE LOSS CONTINGENCY................ 387 112-165 PA POWER OUT LOSS CONTINGENCY................ 390 112-209 SWITCH FROM LOW TO HIGH FREQUENCY OPTION...... 400 112-219 SWITCH FROM HIGH TO LOW FREQUENCY OPTION...... 403 112-229 COMM LCC PROCEDURES COMPLETE.................. 405 112-230 TACAN CHANNEL SELECT (59Y).................... 405 112-236 TACAN MULTIPATH VERIFICATION (OPTIONAL)...... 407 112-245 FLIGHT CREW LOSS OF COMMUNICATION............ 408 113-000 INST LCC WORKAROUNDS.......................... 411 113-001 GENERAL INSTRUCTIONS FOR INST LCC WORKAROUNDS 411 113-002 INS-01/PCM POWER STATUS...................... 415 113-003 INS-01/PCM MTU BITE.......................... 416 113-004 INS-01/FETCH PROM PARITY...................... 417 113-005 INS-01/128KB FORMATER........................ 418 113-006 INS-01/INPUT DATA VALID...................... 419 113-007 INS-01/RAM PARITY............................ 420 113-008 INS-01/TOGGLE BUFFER PARITY.................. 421 113-009 INS-01 PCMMU BITE BIT 14 - NO RESPONSE COMPUTER BUS V75X2134D........................ 422 113-010 INS-02/OPS 1 BITE............................ 423 113-011 INS-02/OPS 1 TEMP............................ 424 113-012 INS-02/OPS 1 MOTION.......................... 425 113-013 INS-02/OPS 2 BITE............................ 426 113-014 INS-02/OPS 2 TEMP............................ 427 113-015 INS-02/OPS 2 MOTION.......................... 428 113-016 INS-02/OPS 1 & 2 BITE........................ 429 113-017 INS-03/MTU AMP 1.............................. 430 113-018 INS-03/MTU AMP 2.............................. 431 113-019 INS-03/MTU FREQ DIFF.......................... 432 113-020 INS-03/MTU TEMP 1............................ 433 113-021 INS-03/MTU TEMP 2............................ 434 113-022 INS-03/MTU PS 1 VOLT.......................... 435 113-023 INS-03/MTU PS 2 VOLT.......................... 436 113-024 INS-03/MTU CMD CHAN A........................ 437 113-025 INS-03/MTU CMD CHAN B........................ 438 113-026 INS-03/MTU CMD CHAN C........................ 439 113-027 INS-03/MTU IRIG-B............................ 440 113-028 INS-03/MTU DIV 1.............................. 441 113-029 INS-03/MTU DIV 2.............................. 442 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 113-030 INS-03/MTU DIV 3.............................. 443 113-031 INS-04/DSC BITE FAIL.......................... 444 113-032 INS-05/MDM WRAP FAIL.......................... 445 113-033 INS-06/C/W FAILURE............................ 446 113-034 LCC SRM-11 - SRM CASE ACREAGE TEMPERATURE ANOMALY...................................... 447 113-035 NON LCC/RCD START UNCOMMAND.................. 448 113-036 NON LCC/RECORD MODE MUX FAIL.................. 449 113-037 NON LCC/DSC-MDM CARD FAIL.................... 450 113-038 NON LCC/CW LIGHT BULB FAIL.................... 451 113-039 NON LCC/RECORDER RUNTIME...................... 452 113-040 NON LCC/MADS ACTIVATION FAIL.................. 453 113-041 NON LCC/OI DATA DROPOUT...................... 454 113-042 NON LCC/GLS PCM TO GSE CNTL NOT PERFORMED.... 455 113-043 NON LCC/GLS PCM TO GSE CNTL NOT CONFIRMED.... 456 113-044 SCM FEEDBACK NOT FA OR 99.................... 457 113-045 INSTRUMENTATION DETAILED WORKAROUND STEPS.... 458 113-046 DETAIL A - PCM SWITCH TO ALTERNATE PCM........ 458 113-052 DETAIL B - TFL RELOAD FOR FLIGHT.............. 461 113-068 DETAIL C - OPS 1 AND 2 BITE VERIFICATION...... 464 113-080 DETAIL D - PSP VERIFICATION.................. 467 113-106 DETAIL E - FMSP 1 VERIFICATION................ 474 113-116 DETAIL F - FMSP 2 VERIFICATION................ 476 114-000 EPDC.......................................... 479 114-001 FUEL CELL AND MAIN BUS VOLTAGE FAILURE (REF SSID EPDC-01)................................ 479 114-002 CONTROL BUS SOURCE FAILURE (REF SSID EPDC-02) 480 114-003 AC CURRENT MEASUREMENTS FAILURE (REF SSID EPDC-04)...................................... 481 114-004 ESSENTIAL BUS SOURCE FAILURE (REF SSID EPDC-06)...................................... 482 114-005 MEC CORE "B" POWER (REF SSID EPDC-08)........ 483 115-000 GNC.......................................... 485 115-001 FWD RHC COMMAND ANOMALY (GNC-01).............. 485 115-002 ORBITER RATE GYRO POWER ANOMALY (GNC-08)...... 486 115-003 ACCELEROMETER POWER ANOMALY (GNC-09).......... 487 115-004 ACCELEROMETER POWER ANOMALY (GNC-09) CONT'D.. 488 115-005 ACCELEROMETER POWER ANOMALY (GNC-09) CONT'D.. 489 115-006 SRB BUS C POWER (GNC-10)...................... 490 115-007 PROCEDURE FOR LOSS FOR MEAS: V76X4393E1 LEFT SRB BUS C RPC C.............................. 490 115-008 PROCEDURE FOR LOSS FOR MEAS: V76X4394E1 RIGHT SRB BUS C RPC C.............................. 491 115-009 PROCEDURE FOR LOSS OF MEAS: V76X4399E1 LEFT SRB BUS C RPC A.............................. 492 115-010 PROCEDURE FOR LOSS OF MEAS: V76X4390E1 RIGHT SRB BUS C RPC A.............................. 493 115-011 ORBITER RATE GYRO FAIL (GNC-12).............. 494 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 115-014 ACCELEROMETER FAIL (GNC-13).................. 496 115-017 ELEVON ACTUATOR POSITION ANOMALY (GNC-22).... 498 115-018 ELEVON ACTUATOR POSITION ANOMALY (GNC-22) CONT 499 115-019 ELEVON SECONDARY DELTA PRESSURE ANOMALY (GNC-24)...................................... 500 115-020 ELEVON AEROSURFACE PROFILE ANOMALY (GNC-25).. 502 115-021 RUDDER/SPEEDBRAKE POSITION ANOMALY (GNC-26).. 503 115-022 RUDDER/SPEEDBRAKE POSITION ANOMALY (GNC-26) (CONT)........................................ 504 115-023 RUDDER/SPEEDBRAKE SECONDARY DELTA PRESSURE ANOMALY (GNC-27).............................. 505 115-024 RUDDER/SPEEDBRAKE SECONDARY DELTA PRESSURE ANOMALY (GNC-27) (CON'T)...................... 506 115-025 RUDDER AEROSURFACE PROFILE ANOMALY (GNC-28).. 507 115-026 SPEEDBRAKE AEROSURFACE PROFILE ANOMALY (GNC-28)...................................... 508 115-027 ORBITER ASA POWER ANOMALY (GNC-32)............ 509 115-028 FCS CHANNEL FAILURE (GNC-38).................. 511 115-029 AERO SURFACE MSID REF (GNC-38)................ 513 115-030 MPS TVC MSID REF (GNC-38).................... 514 115-031 ORBITER ATVC POWER ANOMALY (GNC-39).......... 515 115-032 MPS TVC ACTUATOR POSITION ANOMALY (GNC-40).... 516 115-033 MPS TVC SECONDARY DELTA PRESSURE ANOMALY (GNC-41)...................................... 517 115-034 MPS TVC SECONDARY DELTA PRESSURE ANOMALY (GNC-41) (CON'T).............................. 518 115-035 OMS GIMBAL PROFILE ANOMALY (GNC-44).......... 519 115-036 TABLE GNC-44.................................. 520 115-037 RCS JET CHAMBER PRESSURE INDICATION ANOMALY (GNC-45, RCS-08).............................. 521 115-038 RCS JET CHAMBER PRESSURE INDICATION ANOMALY (GNC-45, RCS-08) (CONT'D).................... 523 115-039 RCS JET CHAMBER PRESSURE INDICATION ANOMALY (GNC-45, RCS-08) (CONT'D).................... 524 115-040 RCS JET CHAMBER PRESSURE INDICATION ANOMALY (GNC-45, RCS-08) (CONT'D).................... 525 115-041 RCS VERNIER DRIVER OUT FAILURE (GNC-46)...... 526 115-042 MSID TABLE (GNC-46).......................... 527 115-043 RCS VERNIER LOGIC RPC FAILURE (GNC-47)........ 528 115-044 MSID TABLE GNC-47............................ 529 115-045 RCS DRIVER POWER FAILURE (GNC-48)............ 530 115-046 RJD TRICKLE CURRENT ANOMALY (GNC-49).......... 534 115-047 RJD TRICKLE CURRENT ANOMALY (GNC-49) CONT.... 535 115-048 IMU HARDWARE BITE ANOMALY (GNC-56)............ 536 115-049 ORBITER IMU POWER ANOMALY (GNC-57)............ 537 115-050 IMU TEMPERATURE READY ANOMALY (GNC-58)........ 538 115-051 IMU OVER TEMPERATURE INDICATOR (GNC-59)...... 539 115-052 IMU SOFTWARE BITE ANOMALY (GNC-61)............ 540 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 115-053 IMU GYROCOMPASS ANOMALY (GNC-62).............. 541 115-054 IMU GYROCOMPASS 1 ALIGNMENT ANOMALY (GNC-63).. 542 115-055 IMU REQUIREMENTS WHEN IRAMS IN USE (GNC-64).. 543 115-056 IMU TRANSMISSION WORD FAILURE (GNC-66)........ 544 115-057 IMU PRESSURE/COMMUNICATION ANOMALY (GNC-67).. 545 115-058 BRAKE PRESSURE ANOMALY (GNC-79).............. 546 115-059 BRAKE POWER ANOMALY (GNC-80).................. 547 115-060 PROCEDURE FOR LOSS OF MEASUREMENT: V76X5800E1 BRAKE/SKID SUB BUS C/A RPC PWR A.............. 547 115-061 PROCEDURE FOR LOSS OF MEASUREMENT: V76X5805E1 BRAKE/SKID SUB BUS B/C RPC PWR B.............. 548 115-062 PROCEDURE FOR LOSS OF MEASUREMENT: V76X5806E1 BRAKE/SKID SUB BUS B/C RPC PWR C.............. 549 115-063 PROCEDURE FOR LOSS OF MEASUREMENT: V76X5811E1 BRAKE/SKID SUB BUS C/A RPC PWR C.............. 550 115-064 LANDING GEAR ANTI-SKID ANOMALY (GNC-81)...... 551 115-065 ANTI-SKID FAIL LIGHT ANOMALY (GNC-82)........ 552 115-066 NOSEWHEEL ANOMALY (GNC-83).................... 553 115-067 NOSEWHEEL ANOMALY (GNC-83) CONT'D............ 554 115-068 NOSEWHEEL ANOMALY (GNC-83) CONT'D............ 555 115-069 NOSEWHEEL ANOMALY (GNC-83) CONT'D............ 556 115-070 NOSE WHEEL POSITION SIGNAL PATH ANOMALY (GNC-84)...................................... 557 116-000 MECHANISMS.................................... 559 116-001 ET UMBL DR CENTERLINE LATCH LOCKED INDICATION FAILED OFF S/B ON............................ 559 116-046 ET UMBL DR CENTERLINE LATCH STOW INDICATION FAILED ON S/B OFF............................ 574 116-075 ET UMBILICAL DOOR CLOSE INDICATION FAILED ON S/B OFF...................................... 585 116-087 ET UMBILICAL DOOR OPEN INDICATION FAILED OFF S/B ON........................................ 590 116-101 ET UMBL DR LATCH - LATCH INDICATION FAILED ON S/B OFF...................................... 595 116-119 ET UMBILICAL DR LATCH - RELEASES INDICATION FAILED OFF S/B ON............................ 602 116-133 RADIATOR DEPLOY INDICATION FAILED ON S/B OFF.. 608 116-140 RADIATOR STOW INDICATION FAILED OFF S/B ON.... 613 116-150 RADIATOR LATCHES - LATCH INDICATION FAILED OFF S/B ON........................................ 618 116-172 RADIATOR LATCHES RELEASE INDICATION FAILED ON S/B OFF...................................... 628 116-179 PAYLOAD BAY DOOR OPEN INDICATION FAILED ON S/B OFF.......................................... 631 116-199 PLB DR BKHD LCH "LATCH" INDICATION FAILED OFF S/B ON........................................ 638 116-224 PLB DR RT FWD BKHD LCH MOTOR 1 CHECK AC - ON.. 646 116-230 PLB DR RT FWD BKHD LCH MOTOR 2 CHECK WITH AC - ON............................................ 647 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 116-252 PLB DR BKHD LCH "RELEASE" INDICATION FAILED ON S/B OFF...................................... 652 116-284 PLBD READY TO LATCH INDICATION FAILED OFF S/B ON............................................ 663 116-285 PLB DR CENTERLINE LCH "LATCH" INDICATION FAILED OFF S/B ON............................ 663 116-290 PLB DR C/L LCH 1-4 MOTOR 1 CHECK AC - ON...... 667 116-337 PLB DR CENTER LINE LCH "RELEASE" INDICATION FAILED ON S/B OFF............................ 678 116-369 LANDING GEAR/DOOR UPLOCK INDICATION FAILED OFF S/B ON........................................ 689 116-374 LANDING SHUTTLE VALVE INDICATION FAILED OFF S/B ON (SSID: AFM-11)........................ 692 116-394 PRMS SHOULDER STOW INDICATION FAILED OFF S/B ON............................................ 700 116-405 PORT RMS SHLD DEPLOY INDICATION FAILED ON S/B OFF.......................................... 706 116-412 PORT RMS RETN LCH "RELEASE" INDICATION FAILED ON S/B OFF.................................... 709 116-419 PRMS LCH "LATCH" INDICATION FAILED OFF S/B ON 712 116-434 STAR TRACKER DOOR CLOSE INDICATION FAILED OFF S/B ON........................................ 718 116-448 STAR TRACKER DOOR OPEN INDICATION FAILED ON S/B OFF...................................... 722 116-459 ADP DOOR "STOW" INDICATION FAILED OFF S/B ON.. 725 116-474 ADP DOOR "DEPLOY" INDICATION FAILED ON S/B OFF 730 116-498 FORWARD MOTOR CONTROL ASSEMBLY................ 736 116-505 CONCLUSION/RECOMMENDATION.................... 738 116-506 MID MOTOR CONTROL ASSEMBLY OPERATIONAL STATUS ANOMALY (AFM-17).............................. 739 116-518 CONCLUSION/RECOMMENDATION.................... 744 116-519 AFT MOTOR CONTROL ASSEMBLY OPERATIONAL STATUS ANOMALY (AFM-18).............................. 745 116-526 CONCLUSION/RECOMMENDATION.................... 747 116-527 HATCH LEAK CHECK FAILURE (CONTINGENCY)........ 763 116-579 LIMIT SWITCH VERIFICATION FAILURE (CONTINGENCY)................................ 783 116-656 HATCH ACTUATOR LOCKING LEVER OVERCENTER VERIFICATION FAILURE.......................... 809 116-675 HATCH ACTUATOR LOCKING LEVER OVERCENTER VERIFICATION FAILURE.......................... 814 116-689 HATCH PAWL FAILURE (CONTINGENCY).............. 818 116-700 I/E HATCH HANDLE REMOVAL (CONTINGENCY)........ 821 116-706 I/E HATCH CARRIER PANEL (CONTINGENCY)-3...... 823 117-000 LAUNCH POLYNOMIAL UPDATE OPTION.............. 837 117-001 G1 LAUNCH POLYNOMIAL UPDATE OPTION............ 837 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 118-000 PAYLOAD RETENTION LATCHES.................... 849 118-039 TABLE 1 - MID MCA OP STATUS.................. 867 119-000 RANGE SAFETY AND SRB SECURING (POST G9 TRANSITION).................................. 927 120-000 INTEGRATED.................................... 929 120-001 CONTINGENCY/RED CREW DEVELOPMENT AND IMPLEMENTATION PROCESS........................ 929 120-002 POST CRYOGENIC LOADING PAD ACCESS............ 930 120-033 CONTINGENCY CREW ENTRY AFTER ECS CONFIGURED TO GN2 FLOW MODE................................ 941 120-062 MLP RE-ENTRY DURING POST LAUNCH SECURING...... 952 120-065 SECURE GN2 SUPPLY TO MLP...................... 954 121-000 LPS.......................................... 963 121-001 C1 CONSOLE RECOVERY PROCEDURE................ 964 121-019 C2 CONSOLE RECOVERY PROCEDURE................ 968 121-040 C3 CONSOLE RECOVERY PROCEDURE................ 973 121-063 C4 CONSOLE RECOVERY PROCEDURE................ 980 121-088 C5 CONSOLE RECOVERY PROCEDURE................ 989 121-108 C6 CONSOLE RECOVERY PROCEDURE................ 993 121-131 C7 CONSOLE RECOVERY PROCEDURE................ 999 121-149 C8 CONSOLE RECOVERY PROCEDURE................ 1003 121-167 C9 CONSOLE RECOVERY PROCEDURE................ 1007 121-181 C10 CONSOLE RECOVERY PROCEDURE................ 1012 121-197 C11 CONSOLE RECOVERY PROCEDURE................ 1018 121-198 C11 CONSOLE RECOVERY PROCEDURE................ 1019 121-225 C12 CONSOLE CRASH FLOWCHART (FIG 121-002) |.. 1031 121-226 C12 CONSOLE CRASH RECOVERY PROCEDURE.......... 1032 121-291 MSTR CONSOLE RECOVERY PROCEDURE.............. 1047 121-315 INTG CONSOLE RECOVERY PROCEDURE.............. 1061 121-335 INTEGRATION CRASH RECOVERY (T-0600/00 THRU T-0200/00).................................... 1066 121-336 INTEGRATION CRASH RECOVERY (T-0200/00 THRU T-0045/00).................................... 1067 121-337 INTEGRATION CRASH RECOVERY (T-0045/00 THRU T-0005/00).................................... 1068 121-338 INTEGRATION CRASH RECOVERY (T-0230/00 THRU T-0009/00).................................... 1072 121-347 INTEGRATION OR BACKUP CONSOLE CRASH RECOVERY (T-0200/00 THRU T-0005/00).................... 1074 121-355 BKUP CONSOLE RECOVERY PROCEDURE.............. 1076 121-369 BACKUP CRASH RECOVERY (T-0200/00 THRU T-0005/00).................................... 1080 121-370 GPCA FEP RECOVERY PROCEDURE.................. 1083 121-384 GPCS FEP RECOVERY PROCEDURE.................. 1085 121-396 OIA FEP RECOVERY PROCEDURE.................... 1087 121-410 OIS FEP RECOVERY PROCEDURE.................... 1089 121-422 LDB FEP RECOVERY PROCEDURE.................... 1091 121-434 LDB TRANSMISSION SYSTEM RECOVERY PROCEDURE.... 1093 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 121-444 LDB TRANSMISSION SYSTEM RECOVERY PROCEDURE (LCC LPS 4-17)................................ 1095 121-445 GS___ FEP RECOVERY PROCEDURE.................. 1096 121-456 GOAL/SYSTEM SOFTWARE RECOVERY FOR TOTAL FEP LOSS.......................................... 1098 121-468 PDR RECOVERY PROCEDURE........................ 1102 121-471 RF DATA LOSS RECOVERY PROCEDURE.............. 1103 121-475 HARDLINE DATA LOSS RECOVERY PROCEDURE........ 1104 121-480 RF DATA INTERRUPTION RECOVERY PROCEDURE...... 1105 121-490 HL DATA INTERRUPTION RECOVERY PROCEDURE...... 1107 122-000 HIM LOSS AFTER T-8 HOURS...................... 1109 123-000 SRSS VEHICLE AGC LEVEL VERIFICATION (MULTIPATH INTERFERENCE)................................ 1187 124-000 GLS.......................................... 1193 124-006 GLS REAL TIME MASK/RESET AND CONTINGENCY LAUNCH SEQUENCE COMMANDS...................... 1194 125-000 LCC WORKAROUND FOR FIREX LOOP AND TANK T-3 PRESSURE ANOMALY - LCC EGR-03................ 1215 125-008 WORKAROUND FOR FIREX PUMP FAILURE - T-09 MINUTES TO T-31 SECONDS...................... 1218 125-011 WORKAROUND FOR FIREX PUMP FAILURE - T-09 MINUTES TO T-31 SECONDS...................... 1219 126-000 CRIM VISUAL ALARM RESET WORKSTEPS............ 1225 127-000 STL BLOWN FUSE REPLACEMENT.................... 1229 128-000 LOSS OF FACILITY AIR COMPRESSOR.............. 1231 129-000 ROEU HOOK ANOMALY (SSID ROEU-01).............. 1233 130-000 ROEU RELAX ANOMALY (SSID: ROEU-02)............ 1265 131-000 ROEU STOW ANOMALY (SSID: ROEU-03)............ 1281 SECTION V - POST OPERATION INSTRUCTIONS NA APPENDICES A THRU Y .............................................. NA Z EMERGENCY INSTRUCTIONS ....................... 1297 132-000 EMERGENCY INSTRUCTIONS - INTEGRATED.......... 1297 132-001 LOSS OF ORBITER GROUND COOLING................ 1297 132-002 INITIAL CONFIG FOR LOSS OF GROUND COOLING CONTROL SEQ.................................. 1299 132-024 SYSTEMS DEACTIVATION FOR LOSS OF GROUND COOLING CONTROL SEQ.......................... 1306 132-038 SYSTEMS DEACTIVATION FOR LOSS OF GROUND COOLING CONTROL SEQ.......................... 1309 132-122 TOTAL LOSS OF COOLING EXPEDITED POWER DOWN.... 1330 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 132-140 FLIGHT AND GROUND CREW EMERGENCY EGRESS/ESCAPE 1334 132-158 RCS/OMS HELIUM REGULATOR LEAKAGE/FAILURE...... 1341 133-000 EMERGENCY INSTRUCTIONS - TEST SUPPORT........ 1343 133-001 EMERGENCY FIREX WATER FLOW.................... 1343 133-004 GO2/GH2 EMERGENCY SHUTDOWN.................... 1348 133-011 LOSS OF AIR LIQUIDE GN2 SUPPLY (HPGN2 AND LPGN2) DURING EXTERNAL TANK LOADING/DRAINING.. 1349 133-027 FIRE ANNUNCIATIONS............................ 1358 134-000 EMERGENCY INSTRUCTIONS - ORBITER.............. 1417 134-001 EMERGENCY SHUTDOWN - ORBITER - ELECTRICAL POWER SYSTEM.................................. 1417 134-002 EMERG ORBITER POWER DOWN - LPS................ 1417 134-018 EMERGENCY MLP AND PAD P/S POWER DOWN - MANUAL - MLP/PAD.................................... 1421 134-026 ORBITER EMERGENCY POWER DOWN - SAFING PANEL.. 1424 134-036 CONFIGURE PAYLOAD PRIMARY TO MAIN B.......... 1426 134-049 RECONFIGURE PAYLOAD PRIMARY TO MAIN C........ 1429 134-063 FUEL CELL EMERGENCY PWR DOWN (MANUAL)........ 1432 134-105 FUEL CELL EMERGENCY PWR DOWN (REMOTE)........ 1444 134-174 POSSIBLE FIRE IN AV BAYS 1,2 OR 3A............ 1460 134-182 PREDETERMINED FIRE INDICATION IN CREW MODULE.. 1463 134-188 FREON COOLANT LOOP UNDERTEMP EMERGENCY PROCEDURE.................................... 1467 135-000 EMERGENCY INSTRUCTIONS - MPS/LOX.............. 1471 135-001 INADVERTENT OPENING OF A86462 TSM DRAIN VALVE DURING LOADING (OXYGEN 65).................... 1471 135-004 PV10 INBD LOX F/D VALVE OR PV9 OUTBD LOX F/D VALVE AND PV19 LOX OVERBOARD BLEED VALVE FAILED CLOSED (OXYGEN 66).................... 1472 135-008 LOSS OF BLEED FLOW FROM VEHICLE WITH NO LOSS OF DRAIN CAPABILITY (OXYGEN 67).............. 1473 135-014 MAJOR OXYGEN LEAK (10,000 PPM OR GREATER) IN THE ORBITER AFT FUSELAGE (OXYGEN 68).......... 1475 135-032 INADVERTENT ET GUCP SEPARATION (OXYGEN 69).... 1480 135-035 MAJOR LEAK/FIRE IN LOX STORAGE TANK PRESSURIZATION LINES (OXYGEN 70).............. 1481 135-038 MAJOR LEAK/FIRE BETWEEN A141 AND A126 OR A126 LOCKUP/OUT OF CONTROL (OXYGEN 71)............ 1481 135-041 MAJOR LEAK/FIRE BETWEEN A98 AND A127 OR A127 LOCKUP/OUT OF CONTROL (OXYGEN 72)............ 1482 135-044 MAJOR LEAK/FIRE IN LOX STORAGE AREA (OXYGEN 73).......................................... 1482 135-047 MAJOR LEAK/FIRE BETWEEN MLP VALVE SKID AND VEHICLE (OXYGEN 74).......................... 1482 135-050 INADVERTENT LO2 T-0 CARRIER PLATE SEPARATION (OXYGEN 75).................................. 1483 135-057 HARDWIRE SYSTEM SAFING (OXYGEN 76)............ 1484 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 135-060 EMERGENCY PWR SHUTDOWN (LOX FACILITY) LPS (OXYGEN 77).................................. 1484 135-066 INITIATION/SAFING OF ORBITER PAD WATER SPRAY SYSTEM - LPS (OXYGEN 79)...................... 1488 135-071 LO2 ET VENT AREA FIRE DURING LOADING (OXYGEN 80).......................................... 1491 135-073 DRAIN WITH LOX ET VENT AND RELIEF VALVE FAILED OPEN (OXYGEN 81).............................. 1491 135-075 EXCESSIVE GASEOUS OXYGEN CONCENTRATION IN ET INTERTANK (LCC PAGE HAZ-07) (OXYGEN 82)...... 1492 135-090 ABRUPT TOTAL LOSS OF ORBITER POWER (OXYGEN 83) 1496 135-095 IMMINENT TOTAL LOSS OF ORBITER POWER (OXYGEN 84).......................................... 1499 135-105 GRADUAL LOSS OF GN2 OR GHE (OXYGEN 86)........ 1502 135-107 TOTAL LOSS OF GN2 (ANY AREA) (OXYGEN 87)...... 1502 135-109 TOTAL LOSS OF GHE IN ANY AREA (OXYGEN 88).... 1502 135-112 LOSS OF POWER - MLP ONLY (OXYGEN 89).......... 1502 135-114 LOSS OF GSE POWER - STORAGE AREA AND/OR PTCR (OXYGEN 90).................................. 1503 135-116 LARGE ACREAGE LOSS OF LOX ET TPS (OXYGEN 91).. 1503 135-118 LOSS OF HELIUM INJECT (OXYGEN 92)............ 1503 135-120 GO2 VENT HOOD EMERGENCY/CONTINGENCY LIFT/ LOWER (OXYGEN 94)............................ 1503 135-125 SSME OPOV OR MOV LEAKAGE (OXYGEN 95).......... 1504 135-130 LOSS OF GPC/OI LINES (OXYGEN 98).............. 1504 136-000 EMERGENCY INSTRUCTIONS - MPS/LH2.............. 1505 136-001 LEAK INDICATION IN LH2 TSM (LH2 106).......... 1505 136-004 LEAK INDICATION ON T-0 UMBILICAL (LH2 107).... 1505 136-007 LEAK ON LH2 ET VENT UMBILICAL QD (LH2 108).... 1506 136-011 MAJOR HYDROGEN (10,000 PPM OR GREATER) LEAK IN THE ORBITER AFT FUSELAGE (HYDROGEN 109)...... 1507 136-024 SSME LEAKAGE, MFV LEAKAGE AND HPFTP LIFT OFF SEAL LEAKAGE (LH2 110)........................ 1510 136-027 MAJOR LEAK/FIRE INDICATION AT ORBITER/ET LH2 DISCONNECT (FD44, FD45, LD54, LD55) (LH2 111) 1511 136-037 MAJOR LEAK/FIRE IN TANK PRESSURIZATION LINES BETWEEN VAPORIZER INLETS AND A3338 (PRE-CONDITION VENT) VLV (LH2 112)............ 1514 136-040 MAJOR LEAK/FIRE BETWEEN A3301 (XFER LINE) VLV OR A3309 (XFER LINE CHILLDOWN) VLV AND MLP VLV SKID (LH2 113)................................ 1515 136-043 MAJOR LEAK/FIRE BETWEEN MLP VLV SKID AND T-0 UMBILICAL DISCONNECT (LH2 114)................ 1516 136-046 MAJOR LEAK/FIRE IN MLP/FACILITY VENT (LH2 115) 1516 136-049 MAJOR LEAK/FIRE IN LH2 ET VENT SYSTEM (LH2 116).......................................... 1517 136-052 INADVERTENT TSM T-0 LH2 CARRIER PLATE SEPARATION (LH2 117).......................... 1518 136-055 INADVERTENT I/T UMBILICAL RELEASE (LH2 118).. 1519 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 136-058 HARDWIRE SYSTEM SAFING (LH2 119).............. 1519 136-061 MPS HARDWIRE DRAIN (LH2 120).................. 1520 136-066 ET VENT VALVE FAILURE (VALVE FAILED OPEN) (LH2 121).......................................... 1521 136-068 ET VENT VALVE FAILED CLOSED DURING FILL (VENT VALVE CYCLING ACTIVE) (LH2 123).............. 1521 136-070 LOSS OF FEP GS1A (LH2 124).................... 1521 136-072 LOSS OF FEP GS2A (LH2 125).................... 1522 136-074 LOSS OF OI LINK (LH2 126).................... 1522 136-076 LOSS OF GPC (LH2 127)........................ 1522 136-078 LOSS OF CRITICAL PURGES (LH2 128)............ 1523 136-080 EXCESSIVE GASEOUS OXYGEN OR HYDROGEN CONCENTRATION IN ET/IT (LH2 129).............. 1524 136-084 IMMINENT TOTAL LOSS OF ORBITER POWER (LH2130) 1525 136-092 GRADUAL LOSS OF GN2 OR GHE (ANY AREA) (LH2 131).......................................... 1527 136-094 TOTAL LOSS OF STORAGE AREA GN2 (LH2 132)...... 1528 136-096 TOTAL LOSS OF FSS GN2 (LH2 133).............. 1528 136-098 TOTAL LOSS OF MLP GN2 (LH2 134).............. 1528 136-100 TOTAL LOSS OF GN2 (ALL AREAS) (LH2 135)...... 1528 136-102 TOTAL LOSS OF FSS GHE (LH2 136).............. 1528 136-104 TOTAL LOSS OF MLP GHE (LH2 137).............. 1528 136-106 TOTAL LOSS OF GHE (ALL AREAS) (LH2 138)...... 1529 136-108 LOSS OF STORAGE AREA POWER (LH2 139).......... 1529 136-110 LOSS OF FSS POWER (LH2 140).................. 1529 136-112 LOSS OF MLP POWER (LH2 141).................. 1529 136-114 LOSS OF ALL POWER (GSE) (LH2 142)............ 1529 137-000 EMERGENCY INSTRUCTIONS - SRB.................. 1531 137-001 INSTRUCTION 1 - IGNITION S&A DEVICE MANUAL SAFING........................................ 1531 137-008 INSTRUCTION 2 - POWER OFF.................... 1535 137-019 INSTRUCTION 3 - SRSS S&A DEVICE MANUAL SAFING 1537 137-023 INSTRUCTION 4 - LEAK N2H4, SRB AFT SKIRT, SUSPECTED OR CONFIRMED........................ 1539 138-000 EMERGENCY INSTRUCTIONS - LOSS OF FIRING ROOM CONTROL/VISIBILITY............................ 1541 138-001 OPTION A - T-6 HOURS TO T-4 MINUTES.......... 1541 138-026 OPTION B - T-4 MINUTES TO T-31 SECONDS........ 1546 138-057 OPTION C - T-31 SECONDS THRU SSME START...... 1552 139-000 EMERGENCY INSTRUCTIONS - PAYLOADS............ 1563 139-001 INSTRUCTION 1 - IUS EMERGENCY POWER DOWN...... 1563 140-000 P/L POWER DE-ACTIVATION...................... 1565 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE -1| DELETED | 105-031 DELETED -1| 105-032 DELETED -1| 105-033 DELETED | 151 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 105-034 DELETED -1| 152 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 106-008 PROBLEM: H2 TANK PRESS OR HTR -1| CON'T ----------------------------- CNTL PRESS HIGH (SSID PRSD-06) (CONT) ------------------------------ 173 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 106-009 PROBLEM: O2 TANK QUANTITY LOW, H2 --------------------------------- TANK QUANTITY LOW (SSID PRSD-07/08) ----------------------------------- 174 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 106-039 PROBLEM: RLF NOZZLE TEMP HIGH -1| ----------------------------- OR LOW (A OR B) (SSID FCP-06) | ----------------------------- 191 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 106-040 PROBLEM: RLF VLV TEMPS, RLF LINE -------------------------------- TEMPS, ALT LINE TEMPS LOW ------------------------- (SSID FCP-06) ------------- 192 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE -1| APU-20 PERFORM THE NEXT STEP TO EVALUATE A POSSIBLE LEAK | IN THE INJECTOR H2O COOLING TANK. 108-055 CAPU VWF57 1. RECORD INJECTOR H2O TANK PRESS ______PSIA BD V46P0504A1 2. RECORD INJECTOR H2O TANK TEMP ______ DEG F V46T0500A1 3. RECORD INJECTOR H2O LINE TEMP 1 ______ DEG F V46T0501A1 4. RECORD INJECTOR H2O LINE TEMP 2 ______ DEG F V46T0502A1 5. RECORD INJECTOR H2O LINE TEMP 3 ______ DEG F V46T0503A1 6. USING DATA RETRIEVAL, PLOT THE ABOVE PARAMETERS AND DETERMINE IF THE NOTED CHANGE IN PRESSURE CAN BE ATTRIBUTED TO A CHANGE IN TEMPERATURE, OR IF THERE EXISTS A SATISFACTORY EXPLANATION FOR THE PRESSURE CHANGE. NOT PERFORMED ______ 108-056 CAPU IF PERFORMED, EVALUATE THE RESULTS OF THE ABOVE TWO STEPS OF TROUBLE SHOOTING AND MAKE A RECOMMENDATION TO THE OTC AND NTD BASED ON LCC PAGE APU-20 INJECTOR COOLING SYSTEM PRESSURE ANOMALY. NOT PERFORMED ______ 243 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- APU FUEL TANK ISOLATION VALVE -1| ----------------------------- | ANOMALY APU-23 | -------------- | | NOTE | | PERFORM THE NEXT FOUR STEPS | AS REQUIRED TO TROUBLESHOOT A | FUEL ISOLATION VALVE POWER | INDICATOR FAILURE TO INDICATE | ON FOLLOWNG PRE-START. IF THE | POWER INDICATOR CAN NOT BE USED | DUE TO A FAILURE, FUEL ISO VLV | TEMP MAY BE USED TO VERIFY | THAT THE ISOLATION VALVE COIL | IS ENERGENIZED. FUEL ISO VLV | TEMP WILL INCREASE APPROXIMATELY | 1 DEGREE FOR EVERY MINUTE IT | IS OPEN WITH NO FUEL FLOW. | | 108-056A CAPU CRT VWF57 -1| 1. RECORD WHICH APU HAS AN | ANOMALOUS CONDITION. | | APU _____ | | 2. RECORD FUEL ISLN VLV A | PWR __________ V46X0X15E1. | | 3. RECORD FUEL ISLN VLV B | PWR __________ V46X0X34E1. | | 4. RECORD FUEL ISO VLV A TEMP 1 | __________ DEG F V46T1X75A1. | | 5. RECORD FUEL ISO VLV A TEMP 2 | __________ DEG F V46T1X76A1. | | 6. RECORD FUEL ISO VLV B TEMP 1 | __________ DEG F V46T1X73A1. | | 7. RECORD FUEL ISO VLV B TEMP 2 | __________ DEG F V46T1X73A1. | | 243.1 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 108-056B PLT PANEL R2 -1| APU/HYD | APU FU TK VLV ENA | _____ CB - CYCLE OPEN (OFF)/ | CLOSED (ON) | APU FUEL TK VLV | _____ SW - CYCLE CLOSED/OPEN | NOT PERFORMED ______| | 108-056C CAPU CRT VWF57 -1| 1. RECORD WHICH APU HAS AN | ANOMALOUS CONDITION. | | APU _____ | | 2. RECORD FUEL ISLN VLV A | PWR __________ V46X0X15E1. | | 3. RECORD FUEL ISLN VLV B | PWR __________ V46X0X34E1. | | 4. RECORD FUEL ISO VLV A TEMP 1 | __________ DEG F V46T1X75A1. | | 5. RECORD FUEL ISO VLV A TEMP 2 | __________ DEG F V46T1X76A1. | | 6. RECORD FUEL ISO VLV B TEMP 1 | __________ DEG F V46T1X73A1. | | 7. RECORD FUEL ISO VLV B TEMP 2 | __________ DEG F V46T1X73A1. | | 108-056D CAPU IF PERFORMED, EVALUATE THE RESULTS -1| OF THE PREVIOUS THREE STEPS OF | THE TROUBLESHOOTING AND MAKE A | RECOMMENDATION TO THE OTC AND NTD | BASED ON LCC PAGE APU-23, APU FUEL | TANK ISOLATION VALVE ANOMALY. | | NOT PERFORMED ______| 243.2 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- PCA APU CONTROLLER RPC POWER ON ------------------------------- ANOMALY APU-24 -------------- NOTE APU-24 PERFORM THE NEXT TWO STEPS IF REQUIRED TO CONFIRM INSTRUMENTATION FAILURE OF V76X400XE1 PRIOR TO APU START. THE APU AUTO BIT TEST VERIFIES REDUNDANT POWER INTO THE CONTROLLER. 108-057 CAPU VWF47 RECORD CONTROLLER PWR J1 RPC ______ V76X400XE1 (X=1, 4 OR 8) RECORD CONTROLLER PWR J2 RPC ______ V76X400XE1 (X=2, 5 OR 7) PFK10 KEY - PRESS CRT VERIFY GROUND COMMANDS ARE BEING ISSUED FOR CORRECT APU CURSOR CNTL BITE INITIATE ON CMD XMIT CURSOR KEY - PRESS V46K0X57NL WAIT 60 SECONDS HIGH SPEED A ON CMD XMIT CURSOR KEY - PRESS V46K0X29NL HIGH SPEED B ON CMD XMIT CURSOR KEY - PRESS V46KOX49NL PFK11 KEY - PRESS CRT VERIFY BITE COMPLETE ON NOT PERFORMED ______ 244 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 111-003 3. CDPS REVIEW MCDS PROGRAM NOTES, ITEM 15, CON'T (LOCATED AT END OF THIS SEQUENCE). VERIFY ANOMALY DUE TO OCCURRENCE OF A MCDS PROGRAM NOTE CONDITION. RECORD NOTE NO.__________ NOTE IF "CRT BITE" FSM IS NOT EXPLAINED BY PROGRAM NOTE, HOLD COUNT, AND DO NOT PERFORM REMAINDER OF THIS OPTION. 4. CDPS CDR ___KYBD (FAILED DEU KYBD) ITEM E EXEC ITEM A EXEC NOT PERFORMED ______ SS4 5. CDPS CDR PANEL C2 ___CRT SEL SW - ___ (ASSIGN TO GOOD CRT) NOT PERFORMED ______ SS5 6. CDPS CDR ___KYBD (GOOD KYBD) GPC/CRT ___ ___ (REASSIGN FAILED CRT) EXEC NOT PERFORMED ______ SS6 ENTIRE STEP NOT PERFORMED ______ 259 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT STEP IF MCDS ANOMALY WAS PASS "I/O ERROR CRT" FAULT SUMMARY MESSAGE. "I/O ERROR CRT" FSM WITH NO I/O ERROR LOG ENTRIES INDICATES A CHECKSUM MISCOMPARE. 111-004 CDPS RECORD NUMBER OF I/O ERROR LOG ENTRIES ASSOCIATED WITH THIS I/O ERROR CRT FAULT SUM MSG:__________ NOT PERFORMED ______ NOTE -1| HOLD COUNT IF ANOMALY IS "I/O ERROR CRT" FSM AND TWO OR MORE UNEXPLAINED I/O ERRORS HAVE BEEN LOGGED AGAINST THIS MCDS DURING COUNTDOWN. | | IF HOLDING COUNT, DO NOT | PERFORM THE REMAINDER OF | THIS OPTION. | 111-005 CDPS CDR CRT ___ VERIFY GOOD DISPLAY WITH NO ANOMALIES OBSERVED (IE, NO BIG X, DISTORTED CHARACTERS, ETC.). NOT PERFORMED ______ NOTE IN NEXT STEP, ASSIGN KYBD TO FAILED DEU. 111-006 CDPS CDR PANEL C2 ___ CRT SEL SW - ___ NOT PERFORMED ______ 260 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT OPTION IF BFS MCDS ANOMALY OCCURS. IF ANOMALY IS "I/O ERROR CRT" AND GPC LOGGED MULTIPLE I/O ERRORS AGAINST CRT, HOLD COUNT AND DO NOT PERFORM NEXT OPTION. 111-106 9. BFS MCDS ANOMALY RECOVERY ---------------------------- OPTION NOT PERFORMED ______ NOTE DURING PROGRESSION OF THIS OPTION, CDPS WILL RECORD PERTINENT INFORMATION IN ITEM 14 - DEU ANOMALY DATA SHEET, LOCATED AT END OF THIS SEQUENCE. 111-107 OTC CDPS PERFORM RECOVERY FOR MCDS ___ ANOMALY NOTE PERFORM NEXT TWO STEPS IF MCDS ANOMALY WAS BFS "CRT BITE" FSM. 111-108 CDPS REVIEW MCDS PROGRAM NOTES,ITEM 15 (LOCATED AT END OF THIS SEQUENCE). VERIFY ANOMALY DUE TO RE-OCCURRENCE OF MCDS PGM NOTE CONDITION. RECORD PGM NOTE NO.: ____________ NOT PERFORMED ______ 111-109 CDPS CDR PANEL C2 CRT ___ POWER SW - OFF, THEN ON NOT PERFORMED ______ 283 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE -1| PERFORM NEXT STEP IF MCDS ANOMALY WAS BFS "I/O ERROR CRT" | FAULT SUMMARY MESSAGE. "I/O ERROR CRT" FSM WITH NO I/O | ERROR LOG ENTRIES INDICATES A CHECKSUM MISCOMPARE. 111-110 CDPS RECORD NUMBER OF I/O ERROR LOG ENTRIES ASSOCIATED WITH THIS I/O ERROR CRT FAULT SUM MSG:__________ NOT PERFORMED ______ NOTE -1| HOLD COUNT IF ANOMALY IS "I/O ERROR CRT" FSM AND TWO OR MORE UNEXPLAINED I/O ERRORS HAVE BEEN LOGGED AGAINST THIS MCDS DURING COUNTDOWN. | | IF HOLDING COUNT, DO NOT | PERFORM THE REMAINDER OF | THIS OPTION. | 111-111 CDPS CDR CRT ___ VERIFY GOOD DISPLAY WITH NO ANOMALIES OBSERVED (IE, NO BIG X, DISTORTED CHARACTERS, ETC.) NOT PERFORMED ______ NOTE IN NEXT STEP, ASSIGN KYBD TO FAILED DEU. 111-112 CDPS CDR PANEL C2 ___ CRT SEL SW - ___ NOT PERFORMED ______ 284 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE FOLLOWING OPTION WILL TRANSITION DPS BACK TO G9 FROM T-9 MIN CNFG TO SUPPORT CONTINGENCY OPERATIONS, THEN TRANSITION BACK TO G1. REMAINING SHUTTLE SYSTEMS WILL MAINTAIN A T-9 MIN CNFG. PERFORM G9 QUICK RECYCLE IF DPS QUICK G9 RECYCLE IS REQUIRED. 111-152 12. G9 QUICK RECYCLE -------------------- OPTION NOT PERFORMED ______ 111-153 NTD OTC DPS WILL BE TRANSITIONING TO G9 TBC FOR CONTINGENCY OPERATIONS. VERIFY SPE READY TO PROCEED. OTC CGNC CGLS TBC CLOX CLHY NOTE PERFORM NEXT STEP IF BFS STORED PROGRAM COMMANDS HAVE BEEN SENT BUT NOT CLEARED. 111-154 NTD *FLT CLEAR BFS SPC BUFFER. REPORT -1| COMPLETION. NOT PERFORMED ______ 111-155 NTD OTC PERFORM QUICK RECYCLE TO G9. OTC CDPS 297 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 111-156 CDPS CURSOR CNTL (VASP9 PG-B) RETURN TO HOST XMIT CURSOR KEY - PRESS CURSOR CNTL (VASP9 PG-B) INHIBIT LCC MONITORING XMIT CURSOR KEY - PRESS 111-157 CDPS CURSOR CNTL (SAS01 PG-B) DPS INIT DISPLAY (SAS01) XMIT CURSOR KEY - PRESS CURSOR CNTL (SAS01 PG-B) TERMINATE OPS MGR5 (SAS25) XMIT CURSOR KEY - PRESS PFK 2 KEY - PRESS 111-158 CDPS CONSOLE KYBD VASJ6 PERF PGM KEY - PRESS 298 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- G1 TRANSITION ------------- 111-168 NTD OTC TRANSITION BACK TO G1. OTC CDPS NOTE -1 | BFS ONE SHOT DATA TRANSFER MUST BE REPERFORMED IF ANY OF THE FOLLOWING HAVE OCCURRED: -BFS GPC RE-IPL -LAUNCH POLYNOMIAL UPDATE -SRM CHAMBER PRESSURE CAL UPDATE -IMU PREFLIGHT CAL PERFORM NEXT THREE STEPS | IF BFS ONE SHOT DATA TRANSFER REQUIRED. 111-169 CDPS CDR PERFORM PASS/BFS TRANSFER PREP -1| PER YOUR CHECKLIST. | | NOT PERFORMED ______ 111-170 CDPS CRT (VASJ6 PG-B) -1| ONE SHOT ENABLED - INVERT GREEN | NOT PERFORMED ______ | 111-171 CDPS PFP (VASJ6) -1| PFPK1 KEY (ONE SHOT SELECT) - PRESS CRT (VASJ6 PGB) ONE SHOT COMPLETE MILESTONE IN INVERT GREEN NOT PERFORMED ______| 301 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 111-172 DELETED -1| | 111-173 CDPS PFP (VASJ6) PFPK3 KEY - PRESS (OPS 101 SELECT) CRT (VASJ6) VERIFY MESSAGES: "OPS TRANSITION IN PROGRESS" "PASS IN 101, ACTIVE DOWNLIST" 111-174 CDPS OTC PASS G1 TRANSITION COMPLETE. DPS OTC NTD READY FOR BFS TRANSITION TO G1. 111-175 OTC CDR TAKE BFS TO OPS 1 PER YOUR CHECKLIST. NOTE DUMP AND COMPARE WILL TAKE APPROXIMATELY TEN MINUTES. 111-176 CDPS PFP (VASJ6) PFPK5 KEY - PRESS (T-20M D&C SELECT) 111-177 CDPS OTC G1 DUMP AND COMPARE IN PROGRESS. 111-178 CDR OTC BFS OPS 1 TRANSITION COMPLETE. 111-179 CVFS CRT (VASB9) VERIFY BFS TRACKING PASS ON FC 1-4 VERIFY NSP STAT GOOD 111-180 CVFS NTD READY FOR BFS UPLINK. 111-181 NTD *FLT PERFORM BFS PREFLIGHT UPLINK LOADING. REPORT COMPLETION. 111-182 OTC PLT CONFIGURE PASS AND BFS HORIZONTAL SITUATION DISPLAYS. REPORT COMPLETION. 302 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 111-183 OTC CDR CONFIGURE YAW STEERING PER YOUR CHECKLIST. REPORT COMPLETION. 111-184 CVFS NTD T-20 MIN GPC DUMP IS COMPLETE. NTD OTC NOTE PERFORM NEXT STEP IF EXPECTED MISCOMPARES OCCUR. 111-185 CDPS APPL PAGE (VASJ6 PG-B) PFK 3 KEY - PRESS NOT PERFORMED ______ NOTE PERFORM NEXT STEP IF UNEXPECTED MISCOMPARES OCCUR. 111-186 CDPS APPL PAGE (VASJ6 PG-B) PFK 2 KEY - PRESS NOT PERFORMED ______ 111-187 CDPS CURSOR CNTL (SAS01 PGB) DPS INIT DISPLAY XMIT CURSOR KEY - PRESS CURSOR CNTL (SAS01 PGB) ACTIVATE OPS MGR 5 (SAS25) XMIT CURSOR KEY - PRESS PFK2 KEY - PRESS NOTE -1| PERFORM NEXT STEP IF BFS SPC | BUFFER WAS CLEARED FOR QUICK RECYCLE OPTION. 111-188 NTD *FLT TRANSMIT BFS STORED PROGRAM COMMANDS. REPORT COMPLETION. NOT PERFORMED ______ 303 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE PERFORM NEXT TWO STEPS TO CLEAR RSLS HOLD FLAG, V90X8667X1, WHICH WILL HAVE BEEN INITIALIZED TO ON BY RSLS AT G9 TO G1 TRANSITION AND WILL BE CLEARED UPON INITIAL LAUNCH SEQUENCE RESUME COMMAND. 111-189 CGLS VERIFY MSRB MILESTONE INHIBITED DUE TO RSLS HOLD FLAG. 111-190 CGLS CONSOLE KYBD PFP (RESUME) PFPK1 - PRESS PFP (RESUME EXECUTE) PFPK6 - PRESS VFY GND AND ONBOARD CLOCKS RESUME AND RE ENTER HOLD AT T-9 MIN. 111-191 OTC CGLS REVIEW EXPECTED HITS AND RESET AS REQUIRED. 111-192 G9 QUICK RECYCLE COMPLETE. G9 QUICK RECYCLE COMPLETE ------------------------- 304 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 114-004A ESSENTIAL BUS SOURCE FAILURE ---------------------------- (REF SSID EPDC-07) ------------------ 482.1 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- THIS PAGE INTENTIONALLY BLANK 482.2 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 117-000 LAUNCH POLYNOMIAL UPDATE OPTION ------------------------------- NOTE PERFORM G1 LAUNCH POLYNOMIAL UPDATE OPTION IF CURRENTLY IN G1 AND LAUNCH POLYNOMIAL UPDATE IS REQUIRED. 117-001 G1 LAUNCH POLYNOMIAL UPDATE OPTION ---------------------------------- NOT PERFORMED ______ 117-002 NTD OTC DPS WILL BE TRANSITIONING TO G9 FOR TBC LAUNCH POLYMONIAL I-LOAD UPDATE. SPE VERIFY READY TO PROCEED. OTC CGNC CGLS TBC CLOX CLHY NOTE PERFORM NEXT STEP IF BFS STORED PROGRAM COMMANDS HAVE BEEN SENT BUT NOT CLEARED. 117-003 NTD *FLT CLEAR BFS SPC BUFFER. REPORT -1| COMPLETION. | NOT PERFORMED ______ 837 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 117-004 *FLT NTD STARTING ADDRESSES FOR CVFS DOWNLIST DUMP IS: GMT L/O:__________ 117-005 NTD OTC PERFORM QUICK RECYCLE TO G9. OTC CDPS 117-006 CDPS CURSOR CNTL (VASP9 PG-B) RETURN TO HOST XMIT CURSOR KEY - PRESS CURSOR CNTL (VASP9 PG-B) INHIBIT LCC MONITORING XMIT CURSOR KEY - PRESS 117-007 CDPS CURSOR CNTL (SAS01 PG-B) DPS INIT DISPLAY (SAS01) XMIT CURSOR KEY - PRESS CURSOR CNTL (SAS01 PG-B) TERMINATE OPS MGR 5 (SAS25) XMIT CURSOR KEY - PRESS PFK 2 KEY - PRESS 117-008 CDPS CONSOLE KYBD VASJ6 PERF PGM KEY - PRESS 838 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE -1| G9 RECYCLE IS PERFORMED BY SEQUENCER VASJ6. IF BFS IS ACTIVE IN OPS 101, VASJ6 WILL FIRST PROMPT CDR TO PERFORM | A BFS RECYCLE TO OPS 0 STANDBY. | ONCE BFS RECYCLE IS COMPLETE, PROGRAM WILL TRANSITION PASS TO G9 VIA DEU EQUIVALENT. PASS G9 TRANSITION TAKES APPROXIMATELY 90 SECONDS. 117-009 CDPS PFP (VASJ6) PFPK4 KEY - PRESS (COUNTDOWN RECYCLE) FOLLOW RECYCLE PROMPTS CRT (VASJ6 PG-B) VERIFY MSG: "RECYCLE COMPLETE" 117-010 CVFS CURSOR CNTL (SAS10 PGB) FSW DISPLAY SELECT MENU (SDS13) XMIT CURSOR KEY - PRESS 117-011 CVFS CURSOR CNTL (SAS10 PGB) UPLINK MONITOR (VWS14) XMIT CURSOR KEY - PRESS 117-012 CDPS OTC TRANSITION TO G9 COMPLETE. READY FOR OTC NTD LAUNCH POLYNOMIAL UPDATE. 839 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- NOTE NOTED REQUIREMENT IS SATISFIED BY COMPLETION OF TWO OF NEXT SEVEN STEPS. (REQUIREMENT WILL ONLY BE SATISIFIED DURING S0007) OMRS S00FF0.250-A 117-013 NTD *FLT CONFIGURE FOR TWO STAGE COMMAND MANUAL EXECUTE. PERFORM AND VERIFY LAUNCH POLYNOMIAL UPLINK. OMRS S00FF0.250-A 117-014 CDPS CURSOR CNTL (VASP9 PG-B) ACTIVATE LCC MONITORING XMIT CURSOR KEY - PRESS PFK 1 KEY - PRESS 117-015 CDPS APPL PAGE (VASJ6 PG-B) PFK1 KEY - PRESS (RECYCLE CMPLT CONTINUE) PFK1 KEY - PRESS (BSR CONTINUE) PFK1 KEY - PRESS (NBAT CONTINUE) 117-016 CDPS CDR PERFORM PASS/BFS TRANSFER PREP -1| PER YOUR CHECKLIST. | | 117-017 CDPS CRT (VASJ6 PG-B) -1| ONE SHOT ENABLED - INVERT GREEN | | 117-018 DELETED | 117-019 *FLT NTD LAUNCH POLYNOMIAL UPLINK COMPLETE. OMRS S00FF0.250-A 840 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 117-064 COMPLETION OF PREVIOUS NINE STEPS SATISFIES NOTED OMRS REQUIREMENT WHEN PERFORMED DURING S0007. OMRSD S00FF0.250-B NOT PERFORMED ______ 117-065 CVFS PFP (VWS14) PFPK2 - PRESS (RETURN) 117-066 CVFS APPLICATION PAGE (VWS14 PG-B) PFK15 KEY - PRESS (TERMINATE) 117-067 CVFS APPLICATION PAGE (SAS10 PG-B) PFK2 KEY - PRESS 117-068 CGLS REVIEW EXPECTED HITS AND RESET ACCORDINGLY. 117-069 G1 LAUNCH POLYNOMIAL UPDATE OPTION COMPLETE. NOTE -1| PERFORM NEXT STEP IF BFS SPC BUFFER WAS CLEARED FOR | QUICK RECYCLE OPTION. 117-070 NTD *FLT TRANSMIT BFS STORED PROGRAM COMMANDS. REPORT COMPLETION. 847 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- THIS PAGE INTENTIONALLY BLANK 848 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 121-046 CLOX LPS CRT (SLP50 PG-A) 156 VERIFY LO2 SAFING PGM (SAL06) EXECUTING OR COMPLETE. VERIFY FOLLOWING MSGS: SAL06 - LOX CONSOLE IS NOT SUPPORTING SAL06 - LOX LOADING/DRAIN IN PROGRESS, SAFING COMMANDS ISSUED. LOX ET ULLAGE PRESS RSYS TRANSFERRED. NOT PERFORMED ______ LOX IN REVERT OR STOP DRAIN --------------------------- CONFIGURATION COMPLETE ---------------------- NOTE PERFORM NEXT STEP IF C3 CONSOLE FAILED DURING LOADING OR DRAIN AND CONSOLE RSYS TRANSFER NOT SUCCESSFUL. 121-047 LPS NTD C3 CONSOLE TRANSFER WAS NOT -1| 232 SUCCESSFUL. PERFORM HARDWIRE SAFING NTD CLOX PER S1003 OXYGEN 76. | NOT PERFORMED ______ LOX IN BACKUP REPLENISH ----------------------- NOTE PERFORM NEXT TWO STEPS IF LOX IN BACKUP REPLENISH. 121-048 CLOX NTD PERFORMING SAFING PER S1003 -1| 232 OXYGEN 94 - CONSOLE C3 LOSS - LO2 | NTD LPS IN BACKUP REPLENISH. | NOT PERFORMED ______ 975 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 121-049 CLOX LPS LO2 BACKUP REPLENISH CONTROL HAS 156 BEEN PERFORMED BY PGM SA001 AT MASTER CONSOLE. MONITOR FOR ANY EXCEPTION AND NOTIFY CLOX IMMEDIATELY. NOT PERFORMED ______ LOX IN BACKUP REPLENISH COMPLETE -------------------------------- NOTE DO NOT PERFORM NEXT TWO STEPS IS C3 CONSOLE FAILED IN PRE- CHILLDOWN, AFTER T-10 SEC OR IN POST LAUNCH. 121-050 LPS CRT (SLP50 PG-A) VERIFY GREEN MESSAGE: RSYS/SAFING FOR CONSOLE C3 TO BKUP COMPLETE. NOT PERFORMED ______ 121-051 LPS NTD C3 RSYS TRANSFER TO BKUP CONSOLE 232 CTPE COMPLETE. NOT PERFORMED ______ HOT SPARE INITIALIZATION ------------------------ 121-052 LPS C1MC PERFORM FOLLOWING AT MSTR CONSOLE KEYBOARD: 1. A_KU_HSP___(1, 2 OR 3) 2. C PP C3 _ _ 121-053 LPS C1SE AT HSP___(1, 2, OR 3) H/W 1. PERFORM $BMAP C3 2. HALT HSP___ 976 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 121-054 LPS C1MC AT BUFFER ENTER PWA LIMITS IN B/S ___,___; LL _____ UL _____. 121-055 LPS C1SE BOOT CPU #0203 121-056 LPS NTD C3 CONSOLE HOT SPARE INITIALIZATION NTD CLOX COMPLETE. HOT SPARE CONSOLE IS 232 CMPL LOCATED IN CONSOLE______. NOTE DO NOT PERFORM NEXT STEP IF C3 CONSOLE FAILED IN PRE- CHILLDOWN, AFTER T-10 SEC OR IN POST LAUNCH. 121-057 LPS CRT (SLP50 PG-A) VERIFY GREEN MESSAGE: RSYS/SAFING FOR CONSOLE C3 TO C3 COMPLETE. NOT PERFORMED ______ HOT SPARE INITIALIZATION, LOX IN -------------------------------- REVERT OR STOP DRAIN CONFIGURATION ---------------------------------- NOTE PERFORM NEXT TWO STEPS IF LOX IN REVERT OR STOP DRAIN CONFIGURATION. 121-058 CLOX LPS CRT (SLP50 PG-A) 156 WHEN HOT SPARE CONSOLE IS INITIALIZED VERIFY LO2 SAFING PGM (SAL06) EXECUTING OR COMPLETE. VERIFY FOLLOWING MSGS: SAL06 - LOX CONSOLE SUPPORTING SAL06 - LOX RSYS RETURNED TO LOX CONSOLE NOT PERFORMED ______ 977 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 121-059 CLOX NTD SAFING PER OXYGEN 93 - CONSOLE C3 232 LOSS DURING LOAD OR DRAIN COMPLETE. NOT PERFORMED ______ HOT SPARE INITIALIZATION, LOX IN -------------------------------- REVERT OR STOP DRAIN CONFIGURATION ---------------------------------- COMPLETE -------- HOT SPARE CONSOLE INITIALIZATION, --------------------------------- LOX IN BACKUP REPLENISH ----------------------- NOTE PERFORM NEXT TWO STEPS IF LOX IN BACKUP REPLENISH. 121-060 CLOX NTD LOX REPLENISH CONTROL HAS BEEN -1| 232 TRANSFERRED BACK TO C3 HOT SPARE | CONSOLE. LOX SYSTEM IS IN STABLE REPLENISH. NOT PERFORMED ______ 121-061 CLOX NTD SAFING PER OXYGEN 94 - CONSOLE C3 -1| 232 LOSS - LOX IN BACKUP REPLENISH COMPLETE. NOT PERFORMED ______ HOT SPARE CONSOLE INITIALIZATION, --------------------------------- LOX IN BACKUP REPLENISH COMPLETE -------------------------------- 978 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 125-016 JBFX ON NON-LAUNCH PAD FIREX HARDWIRE CWSS BACKUP PANEL, START FIREX BACKUP PUMP P-1 BY PERFORMING THE FOLLOWING: 1. SWITCH POSITION ------ -------- P1 START ON (UP) 2. INDICATOR STATE --------- ----- P1 RUNNING ON (RED) NOT PERFORMED ______ 125-017 JBFX DEACTIVATE NON-LAUNCH PAD FIREX CWSS HARDWAIRE BACKUP PANEL BY PERFORMING THE FOLLOWING: 1. SWITCH POSITION ------ -------- COMMAND POWER OFF (DOWN) 2. INDICATOR STATE --------- ----- COMMAND POWER RED LAMP OFF NOT PERFORMED ______ 1221 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 OPERATION INSTRUCTIONS SEQ TIME CMD RESP DESCRIPTION VERIF. -------- ---------- ---- ---- --------------------------------- -------- 125-018 JBFX ON CONSOLE, NON-LAUNCH PAD -1| SKELETON P2A/P2B, ACTIVATE WSSA | FIREX COMMAND BUS BY | PERFORMING THE FOLLOWING: 1. TAB CURSOR ONTO "NON-FHCP" COMMAND TARGET. 2. PRESS "XMIT CURSOR" KEY. 3. SELECT "PAD ___"/"RESTORE C1 CONFIG" STATE. 4. PRESS "EXEC CMD" KEY. 5. VERIFY: INDICATOR STATE --------- ----- CCS BUS A PWR ON (GREEN) CCS BUS B PWR ON (GREEN) CCS FIREX CMD BUS ON (GREEN) NOT PERFORMED ______ NOTE -1| FOLLOWING STEP WILL BE PERFORMED IF BACKUP PUMP P-1 | IS SUPPORTING. 125-019 JBFX NTD BACKUP PUMP P-1 IS ON LINE. WSSA 212 RECOMMEND CONTINUE WITH COUNT. NOT PERFORMED ______ OPTION A COMPLETE ----------------- 1222 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 APPENDIX Z EMERGENCY INSTRUCTIONS ---------------------- SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- 132-000 EMERGENCY INSTRUCTIONS - INTEGRATED ----------------------------------- 132-001 LOSS OF ORBITER GROUND COOLING ------------------------------ 1297 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- -1| FIGURE 132-001 - LOSS OF ALL THREE SETS OFS70-0509/0510 REFR UNITS 1298 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- 134-000 EMERGENCY INSTRUCTIONS - ORBITER -------------------------------- 134-001 EMERGENCY SHUTDOWN - ORBITER - ELECTRICAL ----------------------------------------- POWER SYSTEM ------------ NOTE ANY OR ALL OF THE FOLLOWING STEPS SHALL BE PERFORMED ONLY UPON DIRECTION OF OTC. 134-002 EMERG ORBITER POWER DOWN - LPS ------------------------------ CAUTION -1| DELETED | 134-003 OTC NTD EMERGENCY POWER DOWN WILL BE PERFORMED. 232 TBC PTC 1417 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- NOTE PERFORM NEXT STEP FOR IUS MISSIONS AND IF IUS IS POWERED UP AND TIME IS AVAILABLE FOR IUS POWER DOWN. (APPROX 20 MINUTES) 134-004 OTC PERFORM IUS EMERGENCY POWER DOWN PER DOP. NOT PERFORMED ______ 134-005 PTC ICTC PERFORM IUS POWER DOWN PER DOP D290-50020-27. -1| REPORT COMPLETION. 134-006 ICTC PTC IUS POWER DOWN PER DOP D290-50020-27 COMPLETE. -1| 134-007 PTC NTD IUS POWER DOWN COMPLETE. 134-008 OTC CEPD PERFORM EMERGENCY ORBITER POWER DOWN. 132 CAUTION IN THE EVENT THE FUEL CELLS ARE SUPPLYING POWER TO THE ORBITER, VERIFY OR PERFORM THE FOLLOWING STEP PRIOR TO EXECUTING AN EMERGENCY POWER DOWN. NOTE PERFORM NEXT STEP IF CREW MODULE MANNED. 134-009 CEPD PLT PANEL R1 POWER DISTRIBUTION ESS BUS SOURCE FC 1 SW - OFF FC 2 SW - OFF FC 3 SW - OFF NOT PERFORMED ______ 1418 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- 134-030 CEPD ORBITER ELECTRICAL SAFING PANEL ORBITER MN A SW - OFF (MOM) MN B SW - OFF (MOM) MN C SW - OFF (MOM) ORBITER MN A OFF LITE ON (MOM) MN B OFF LITE ON (MOM) MN C OFF LITE ON (MOM) ITCU MN A SW - OFF MN B SW - OFF MN C SW - OFF ITCU MN A OFF LITE ON MN B OFF LITE ON MN C OFF LITE ON 134-031 CEPD ORBITER ELECTRICAL SAFING PANEL VOLT/AMPS SELECT SWITCH MN "A" LL MN "B" LL MN "C" LL 134-032 CEPD ORBITER ELECTRICAL SAFING PANEL ITCU PF 1 SW - OFF PF 2 SW - OFF ITCU PF 1 OFF LITE ON PF 2 OFF LITE ON 134-033 CEPD ORBITER ELECTRICAL SAFING PANEL VOLT/AMPS SELECT SWITCH PF-1 LL PF-2 LL 134-034 CEPD OTC ORBITER EMERGENCY POWER DOWN COMPLETE. 132 134-035 OTC CDR VERIFY ORBITER POWER HAS BEEN REMOVED. CEPD CTPE 1425 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- 134-036 CONFIGURE PAYLOAD PRIMARY TO MAIN B ----------------------------------- CAUTION -1| FOR IUS MISSIONS ONLY, PAYLOAD | PRIMARY POWER MUST REMAIN ON | FROM IUS POWER ON THRU LAUNCH. | IF P/L PRI MN C IS LOST BEFORE | L-20 MINUTES, IUS WILL POWER | DOWN. IUS COUNTDOWN MUST BE | REPEATED. AFTER L-20 MINUTES, | IUS WILL SWITCH TO ASE BATTERIES | AND WILL BE NO-GO FOR LAUNCH. | SHOULD ANY LOSS OF P/L PRI MN C OCCUR, NOTIFY PTC IMMEDIATELY. DO NOT REAPPLY P/L PRI POWER WITHOUT NOTIFING PTC. NOTE FOLLOWING STEPS WILL BE RUN PER OTC DIRECTION IN EVENT OF LOSS OF MAIN C POWER FEED TO PAYLOAD PRIMARY BUS AFTER CLOSE OF PAYLOAD BAY DOORS. ORBITER SWITCHES MAY BE CONFIGURED BY SCO, PLT, CDR AND MSI; AS DIRECTED BY ANY OF THE FOLLOWING ENGINEERS: OTC, CPLE, CEPD OR TPE. WHILE ON GND PWR, ONLY ONE MAIN BUS SOURCE (MAIN B OR MAIN C) MAY BE TURNED ON WHEN APPLYING P/L PRI PWR. 134-037 PTC NTD PERFORM P/L PRIMARY MN C POWER DOWN. NTD OTC OTC PLT 1426 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- 134-049 RECONFIGURE PAYLOAD PRIMARY TO MAIN C ------------------------------------- CAUTION -1| FOR IUS MISSIONS ONLY, PAYLOAD | PRIMARY POWER MUST REMAIN ON | FROM IUS POWER ON THRU LAUNCH. | IF P/L PRI MN C IS LOST BEFORE | L-20 MINUTES, IUS WILL POWER | DOWN. IUS COUNTDOWN MUST BE | REPEATED. AFTER L-20 MINUTES, | IUS WILL SWITCH TO ASE BATTERIES | AND WILL BE NO-GO FOR LAUNCH. | SHOULD ANY LOSS OF P/L PRI MN C OCCUR, NOTIFY PTC IMMEDIATELY. DO NOT REAPPLY P/L PRI POWER WITHOUT NOTIFING PTC. NOTE FOLLOWING STEPS WILL BE PER OTC DIRECTION IF PAYLOAD PRIMARY POWER HAS BEEN SWITCHED TO MAIN B. THEY WILL RECONFIGURE PAYLOAD PRIMARY POWER TO NORMAL MAIN C FEED FOR LAUNCH. ORBITER SWITCHES MAY BE CONFIGURED BY SCO, PLT, CDR OR MSI; AS DIRECTED BY ANY OF FOLLOWING ENGINEERS: OTC, CPLE, CEPD OR TPE. WHILE ON GND PWR, ONLY ONE MAIN BUS SOURCE (MAIN B OR MAIN C) MAY BE TURNED ON WHEN APPLYING P/L PRI PWR. 134-050 PTC NTD REQUEST CONCURRENCE TO RECONFIGURE PAYLOAD NTD OTC PRIMARY POWER TO MAIN C. PAYLOAD PRIMARY OTC PLT POWER WILL BE LOST MOMENTARILY. 134-051 OTC PLT PERFORM P/L PRIMARY MN B POWER DOWN. 1429 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- CAUTION MN B CONTR CB WILL APPLY CONTROL POWER TO FUEL CELL NO. 2 MAIN BUS SWITCHES. CAUTION SHOULD BE USED IN POSITIONING FOLLOWING SWITCHES TO AVOID INADVERTANT FUEL CELL ACTIVATION. 134-052 OTC PLT PANEL O13 ROW C ESS 2CA MN C CONTR CB - CLOSE (NOTE IF VERIFIED OR CB CLOSURE REQUIRED) 134-053 OTC PLT PANEL R1 POWER DISTRIBUTION PAYLOAD PRI MN B SW - OFF (MOM) VERIFY: PRI MN B TB OFF NOTE PERFORM THE NEXT STEP IF CB WAS ORGINALLY OPEN. 134-054 OTC PLT PANEL O13 ROW C ESS 2CA MN B CONTR CB - OPEN NOT PERFORMED ______ 134-055 OTC NTD P/L PRIMARY MN B POWER DOWN IS COMPLETE. NTD PTC 134-056 NTD PTC VERIFY READY FOR P/L PRI MAIN C PWR. 134-057 OTC PLT PERFORM P/L PRI MN C PWR UP 1430 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- 135-071 LO2 ET VENT AREA FIRE DURING LOADING ------------------------------------ (OXYGEN 80) ----------- WARNING PAD PERSONNEL - IMMEDIATE SAFETY HAZARD THIS EMERGENCY MAY REQUIRE IMMEDIATE FLIGHT CREW/ GROUND CREW EGRESS AND ESCAPE PER SEQ 132 - EMERGENCY INSTRUCTIONS - INTEGRATED, AT DISCRETION OF NTD. 135-072 CLOX NTD THERE HAS BEEN A FIRE IN LOX ET VENT AREA. TBC STOP FLOW HAS BEEN INITIATED AND ET VENT VALVE HAS BEEN CLOSED (OXYGEN 80). 135-073 DRAIN WITH LOX ET VENT AND RELIEF VALVE --------------------------------------- FAILED OPEN (OXYGEN 81) ----------------------- WARNING THIS EMERGENCY MAY REQUIRE IMMEDIATE FLIGHT CREW/ GROUND CREW EGRESS AND ESCAPE PER SEQ 132 - EMERGENCY INSTRUCTIONS - INTEGRATED, AT DISCRETION OF NTD. 135-074 CLOX NTD ET LOX DRAIN WITH VENT VALVE FAILED OPEN HAS TBC BEEN INITIATED (OXYGEN 81). 1491 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- 135-075 MAJOR PROPELLANT LEAK IN ET/IT (OXYGEN 82) -1| ------------------------------------------ | | WARNING -1| | PAD PERSONNEL - IMMEDIATE | SAFETY HAZARD. | | THIS EMERGENCY SEQUENCE MAY | REQUIRE IMMEDIATE FLIGHT | CREW/GROUND CREW EGRESS AND | ESCAPE PER SEQ 132, EMERGENCY | INSTRUCTIONS - INTEGRATED, AT | THE DISCRETION OF THE NTD. | | 135-076 CHGD NTD THERE IS A MAJOR PROPELLANT LEAK IN THE -1| ET/IT (10,000 PPM OR GREATER O2 OR H2). | EMERGENCY SAFING IS REQUIRED. CONDITION | IS YELLOW. | | 135-077 NTD TBC PERFORM SAFING FOR MAJOR PROPELLANT LEAK -1| TBC CLOX IN ET/IT PER OXYGEN 82. | | 135-078 CLOX TBC ET LOX DRAIN HAS BEEN INITIATED. -1| NTD | | 135-079 CLOX TBC SAFING PER OXYGEN 82 - MAJOR PROPELLANT | TBC NTD LEAK IN ET/IT COMPLETE. | 1492 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- 135-080 DELETED -1| NOTE -1| DELETED | 135-081 DELETED -1| 135-082 DELETED -1| 1493 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- NOTE -1| DELETED | 135-083 DELETED -1| 135-084 DELETED | 135-085 DELETED | 135-086 DELETED -1| 1494 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- NOTE -1| DELETED | 135-087 DELETED | 135-088 DELETED | 135-089 DELETED -1| 1495 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- 135-090 ABRUPT TOTAL LOSS OF ORBITER POWER ---------------------------------- (OXYGEN 83) ----------- WARNING PAD PERSONNEL - IMMEDIATE SAFETY HAZARD. THIS EMERGENCY MAY REQUIRE IMMEDIATE FLIGHT CREW/ GROUND CREW EGRESS AND ESCAPE PER SEQ 132 - EMERGENCY INSTRUCTIONS - INTEGRATED, AT DISCRETION OF NTD. CAUTION THIS SEQUENCE COVERS LOSS OF ALL THREE MAIN ORBITER POWER BUSES DURING EACH PHASE OF LOAD/DRAIN. IN ALL PHASES, THE FOLLOWING FUNCTIONS WILL BE LOST: ET VENT VALVE CLOSED INDICATOR ET ULLAGE PRESSURE (4K, 4L, 4M) MPS VALVE POSITION IND ET LIQUID LEVEL SENSORS AND MPS ECO SENSORS 1496 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- 135-114 LOSS OF GSE POWER - STORAGE AREA AND/OR --------------------------------------- PTCR (OXYGEN 90) ---------------- 135-115 CLOX NTD THERE HAS BEEN LOSS OF POWER IN _____ AREA. TBC REVERT/STOP DRAIN HAS BEEN INITIATED (OXYGEN 90). 135-116 LARGE ACREAGE LOSS OF LOX ET TPS -------------------------------- (OXYGEN 91) ----------- 135-117 CLOX NTD THERE HAS BEEN A LARGE ACREAGE LOSS OF TPS TBC ON LOX ET. STOP FLOW HAS BEEN INITIATED. PERFORMING DRAIN FROM STOP FLOW (OXYGEN 91). 135-118 LOSS OF HELIUM INJECT (OXYGEN 92) --------------------------------- 135-119 CLOX NTD SAFING PER OXYGEN 92 - LOSS OF HELIUM INJECT TBC HAS BEEN PERFORMED. 135-120 GO2 VENT HOOD EMERGENCY/CONTINGENCY LIFT/ -1| ----------------------------------------- LOWER (OXYGEN 95) | ----------------- 135-121 CMEC TBC GO2 VENT HOOD CONTINGENCY HOOD LIFT/LOWER WILL 136 BE INITIATED. REQUEST LOX ET VENT VALVE BE TBC CLOX CLOSED. 135-122 CLOX TBC LOX ET VENT VALVE IS CLOSED. 136 TBC CMEC 135-123 CMEC TBC GO2 VENT HOOD LIFT/LOWER COMPLETE. 136 LOX ET VENT VALVE MAY BE RE-OPENED. TBC CLOX 135-124 CLOX TBC GO2 EMERGENCY/CONTINGENCY HOOD LIFT/LOWER -1| 136 COMPLETE (OXYGEN 95). | TBC NTD 232 1503 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- 135-125 SSME OPOV OR MOV LEAKAGE (OXYGEN 96) -1| ------------------------------------ 135-126 CSME NTD ME-___ LOX SUPPLY LINE TEMP HAS DECREASED OTC BELOW LCC SSME-1 LIMIT. INITIATING SAFING PER OXYGEN 96. | 135-127 CLOX NTD 1. LO2 PREVALVES HAVE BEEN CLOSED TO TBC ISOLATE SSME LEAKAGE. 2. STOP FLOW HAS BEEN INITIATED. REQUEST CONCURRENCE TO INITIATE DRAIN (IF ET LEVEL GREATER THAN 2 PCT). NOT PERFORMED ______ SS2 135-128 NTD CLOX INITIATE LO2 DRAIN PER OMI S1003 TBC (IF ET LO2 LEVEL GREATER THAN 2 PCT). NOT PERFORMED ______ 135-129 CSME NTD LO2 SAFING PER OXYGEN 96 IS COMPLETE. LO2 -1| OTC PREVALVES HAVE BEEN CLOSED AND LO2 DRAIN HAS BEEN INITIATED (IF ET LO2 LEVEL GREATER THAN 2 PCT). CURRENT TREND IS __________. 135-130 LOSS OF GPC/OI LINES (OXYGEN 99) -1| -------------------------------- 135-131 CLOX NTD LOX SYSTEM STOP FLOW HAS BEEN INITIATED DUE TO TBC LOSS OF GPC OR OI LINK. IF LINK IS NOT RESTORED LOX DRAIN (USING LOW RANGE XDUCERS IF GPC FAILED) WILL BE REQUIRED. 1504 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- 136-078 LOSS OF CRITICAL PURGES (LH2 128) --------------------------------- NOTE IF IN DRAIN, CONTINUE IN DRAIN. ONE OF FOLLOWING PURGES HAS BEEN LOST: 1. ET/IT PGE 2. ORB AFT FUSELAGE GN2 PURGE AND PAYLOAD BAY PURGE 3. ET VENT DISC CAVITY PURGE 4. ORB/ET LH2 DISC CARRIER PL PGE 5. T-0 UMBILICAL CAVITY PURGE. 136-079 CLHY TBC ET CRITICAL PURGE __________ MALFUNCTIONED NTD AND TERMINATED. LH2 SYSTEM IN REVERT AND DRAIN BEING INITIATED. 1523 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- 136-080 MAJOR PROPELLANT LEAK IN ET/IT (LH2 129) -1| ---------------------------------------- | | WARNING | | PAD PERSONNEL - IMMEDIATE | SAFETY HAZARD. | | THIS EMERGENCY SEQUENCE MAY | REQUIRE IMMEDIATE FLIGHT | CREW/GROUND CREW EGRESS AND | ESCAPE PER SEQ 132, EMERGENCY | INSTRUCTIONS - INTEGRATED, | AT THE DISCRETION OF THE NTD. | | NOTE -1| | SEVERE OXYGEN LEAKAGE INTO | INTERTANK (SUCH AS RUPTURED | LOX TANK) MAY WARRANT USE OF | EMERGENCY DRAIN. REALTIME | EVALUATION OF SYSTEM IS REQUIRED. | | 136-081 CHGD NTD THERE IS A MAJOR PROPELLANT LEAK IN THE | ET/IT (10,000 PPM OR GREATER O2 OR H2). | EMERGENCY SAFING IS REQUIRED. CONDITION | IS YELLOW. | | 136-082 NTD CLHY PERFORM SAFING FOR MAJOR PROPELLANT LEAK -1| IN ET/IT PER S1004 (SEQ 129). | | 136-083 CLHY NTD ET LH2 DRAIN INITIATED. -1| | 1524 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- 139-000 EMERGENCY INSTRUCTIONS - PAYLOADS --------------------------------- 139-001 INSTRUCTION 1 - IUS EMERGENCY POWER DOWN ---------------------------------------- NOTE IF IUS IS PERFORMING BATTERY CHECKS AND TVC CHECKS, WAIT UNTIL IUS RETURNS TO MAIN C. SCENARIO WILL TAKE APPROXIMATELY 2 MINUTES TO COMPLETE. 139-002 PTC OTC REQUIRE EITHER MS2 AND/OR CEPD SUPPORT 132 ON OIS CHANNEL 134 FOR IUS EMERGENCY POWER DOWN. 139-003 PTC ICTC PERFORM EMERGENCY POWER DOWN FOR IUS. 134 NOTE -1| PERFORM NEXT STEP IF FLIGHT CREW OR SCO IS PRESENT. 139-004 ICTC MS2 PANEL L10-PCP PANEL POWER PRI CB - CLOSE L10CB1 ALT CB - CLOSE L10CB2 IUS CONV POWER PRI SW - OFF L10S1 PRI TB BP L10I1 ALT TB BP L10I31 NOT PERFORMED ______ 1563 VOLUME 5 OF 5 OMI NO. - S0007VL5 DATE: 07-01-99 REV. - Z-1 EMERGENCY INSTRUCTIONS SEQ CMD RESP DESCRIPTION VERIF. -------- ---- ---- ------------------------------------------- -------- NOTE PERFORM NEXT TWO STEPS IF FLIGHT CREW OR SCO IS NOT PRESENT AND COS HAS CONTROL. 139-005 PTC ICTC POWER OFF IUS FROM THE COS. 134 NOT PERFORMED ______ 139-006 ICTC ICC1 COS CRT/KYBD PG, 189 TYPE: 10 (IUS CONV PWR - OFF) ENTER - PRESS NOT PERFORMED ______ 139-007 ICTC PTC IUS IS POWERED OFF. 139-008 PTC NTD IUS IS POWERED DOWN. -1| 1564 DATE: 1999-07-02 15.25.06 S0007VL5 SHUTTLE COUNTDOWN - (LPS) DISTRIBUTION F - FINAL JILL JAHNKOW..........................2 FA-99 BOEING NORTH AMERICAN MISSION SUPPORT ROOM 12214 LAKEWOOD BLVD DOWNEY, CA 90241 CHRIS WEAVER..........................8 PZ-L TOTAL QTY: 287 FOR CHANGES TO THIS DISTRIBUTION LIST, CONTACT: MARY M. HESTER , USK-187, (407) 861-3301 EXT ELIZABETH C. KLOS , USK-187, (407) 861-3430 EXT 1 DATE: 1999-07-02 15.25.06 S0007VL5 SHUTTLE COUNTDOWN - (LPS) DISTRIBUTION F - FINAL AE70/J. HOWARTH NASA/JSC............5 BOEING NORTH AMERICAN C/O TRANSPORTATION OFFICE 12214 LAKEWOOD BLVD BUILDING 420 DOWNEY, CA 90241 HOUSTON, TX 77058 AFQA/LGQAB/P. MCDANIEL ATTN: DA82/MARY C. THOMAS BA/FC-50/W. BRAGG.....................2 BLDG 30M, ROOM 235 BA/FC-51/ELS DATA FILES NN-L/PAYLOAD ENGINEERING BA/FC-51/J. HAGOOD....................2 NN-M1 BA/FC-51/J. LEWIS.....................2 NN-M2 BA/FC-51/N. BIHR......................3 NN-M3 BNA SPACEHAB/NANCY CRABTREE...........2 THIO-LSS/BRIAN ST. AUBIN SPACEHAB, INC USBI-LSS/LIBRARY 620 MAGELLAN RD USK-078/CCC, C-1 PNEU CAPE CANAVERAL, FL 32920 USK-078/CCC, C-1 WATER C07A/J. LECHER USK-078/CCC, C-3 POWER JSC, TX 77058 USK-078/CCC, INTEGRATION EC-B/DAVID SPACEK USK-225/JODI SILLS EI-C-C/NSF CONSOLE USK-391/SAFETY OPS (PAD B) EI-C-C/NSF LC39 PROCEDURES USK-550/VITT OFFICE......2 EI-C-C/PAC CONSOLE ZA03/DAVID BARNES EI-C-D/NASA VAB SAFETY BOEING NORTH AMERICAN EI-C-F/NASA OPF SAFETY 555 DISCOVERY DRIVE EP2/LIBRARY HUNTSVILLE, AL 35806 JSC, TX 77058 3 SLS/DOOT/CAPT. G. FENTRESS ESMC-SEO/CAMPBELL 3 SLS/MA/B. STRACENER....2 LLOYD MUSTIN SSM 45 SPACE WING/SESL/PAFB MAIL STOP AE26 AIR-FORCE CCAFS BOEING NORTH AMERICAN N/A SPACE SYSTEMS DIV. 45 RANS/DOOB P.O. BOX 7009 (CCAFS) DOWNEY, CA 90241-7009 PHILLIPS PARKWAY/10400 MS-E68/R. BAKES PATRICK AFB, FL 32925 THIOKOL CORP. CCC LIBRARY..............3 P.O. BOX 707 USK-093 BRIGHAM CITY, UT 84302-0707 MISSION SUPPORT MV2/D. STAMPER SGS-347 JSC, TX 77058 EG&G PROTECTIVESYSTEMS MV3/KENNETH BROWN BOC-326 JSC, TX 77058 1 DATE: 1999-07-02 15.25.06 S0007VL5 SHUTTLE COUNTDOWN - (LPS) DISTRIBUTION F - FINAL SECTION NASANAVAIDSSYSTEMS SFOC SAFETY-CONSOLE PK-F3 USK-399 SECTION NASACOMM/RFSYSTEMS SUPV-SAFETY RELIABILITY-ENGR PK-F3 USK-291 NASA-FLT ELECTR-SYS-SECT SRS-SSC OPERATIONS-SAFTEY PK-F MU6110 FLOW DIRECTOR-OFFICE TECHNICAL DOC-CTR.......50 PH-B2 USK-038 SECTION NASAECLSSSYSTEM TSMO SITE-MGRS PK-G5 USK-299 BOEING P/L-TEST-CONDUCTOR.............3 TSMO OMD F214 USK-075 GUIDANCE-AND NAVIGATION USA INSTRUMENTATION.....2 USK-195 USK-194 GEL LCC-RM-3R18 USA LAUNCH-OPERATIONS..2 USK-542 USK-C09 LAUNCH DIRECTOR.......................2 VITT OFFICE PH F204 ORB MECHANISM O&C BLDG PK-H5 SWING ARMS-ENG'G NASA QA-FR1 USK-290 USK-268 ET MECHANICAL-ENG OTC ORBTESTCONDUCTOR..................4 USK-251 USK-023 ET LH2PAD-A SPC PAD-SAFETY USK-174 USK-257 ET LH2PAD-B TEST-OPS PAD-A USK-390 USK-307 ET-LOX PAD-A TEST-OPS PAD-B USK-173 USK-389 ET-LOX PAD-B BRANCH INSTRUM.&P/LSYS................2 USK-316 PK-F3 MEQ ORB-MECHANISMS-ENG PNEUMATICS ENGINEERING USK-408 USK-043 OMS/RCS ENG-PADA OFFICE NASAFIRE/RESCUE USK-484 IM-SPS-A OMS/RCS ENG-PADB PAD SWING-ARMS-SHOP USK-347 USK-398 CENTRL WRK-PKG-BLD USK-409 1 DATE: 1999-07-02 15.25.06 S0007VL5 SHUTTLE COUNTDOWN - (LPS) DISTRIBUTION F - FINAL COMM CONTROL..........................2 STEVE GODFREY USK-145 USK-241 TSMO PAD-A BILL NUTTER........5 USK-076 USK-214 TSMO PAD-B JANIENE L. PAPE USK-404 USK-284 TSMO SUPV-STM.........................3 PAUL L. QUANDT USK-299 USK-356 ROBERT T. ROOK II TODD M. GRACOM USK-356 USK-195 FRANK A. DEBERNARDO PAUL R. GRATSCH....2 USK-116 USK-195 NEAL R. GRIFFITH MARK F. DEZENDORF USK-112 USK-285 DON GARCEAU EARL D. COOLEY USK-109 USK-269 THOMAS E. JACOBS......................2 ERIC D. HENRY USK-107 USK-225 JIM TOWNSEND BOB DOUGERT.......2 USK-108 USK-356 SHOE SHOEMAKER DEAN T. TYRE USK-144 USK-421 PAT CHAPPELL E HALL III........3 USK-074 USK-420 DENNIS E. LOHAUS STEVE VELLIGAN USK-069 USK-213 RICHARD H. MURRAY.....................2 RANDY DUNCAN......2 USK-414 USK-196 ROBERT RODRIGUEZ......................2 DON GREEN USK-198 USK-043 ED DICRISTINA RTW/SECUR R. HOEFER USK-305 USK-453 TOM WELLS.............................2 PEGGY S. HATTAWAY USK-420 USK-246 MARTIN L. CARLSON GARY A. WOODS USK-420 USK-281 JUDY HOOPER...........................3 PAUL E. BRANDT USK-247 USK-111 1 DATE: 1999-07-02 15.25.06 S0007VL5 SHUTTLE COUNTDOWN - (LPS) DISTRIBUTION F - FINAL OZZIE FISH PHIL WEBER USK-314 PK-H6 PAUL A. KRAUSE PAT MARKEY USK-214 PK-J ANDY BUNDY RENEE HART PK-E3 USK-669 DAVID R. SCHECHTER DONALD G. SIMMONS PZ-C USK-647 JIMBO BOLTON BOBBY E. ORR......2 USBI-LSS USK-607 BILL CLEVER II OLAN J. BERTRAND SK CA4 KATHLEEN A. CONWAY HOUSTON, TX 77058 USK-669 KEN FORD TERRI L. HERST USK-637 PK-D RICHARD MIZELL ED MANGO PK-F6 PK-D2 ERVIN G. WALKER SCOTT CHANDLER........................2 JCI-VITC-2 PK-E4 ANGELO PACE MICHAEL GARSKE USK-682 DF24 RANDY DAVIES JSC, TX 77058 CSR-3200 STEVE SWICHKOW CAPE CANAVERAL AFS, FL 32899 PK-F6 RONALD W. WETMORE AL DIAZ MMC-15 PK-F ERIC P. GARDZE BOB BEIL ROC-OSB PK-G3 HAROLD E. REED ANDY DIBBERN JJ-3-B PK-G6 JEFF LEVITT PATRICIA E. GLADNEY F256 PK-G5 CHUCK GIVENS PETE CHITKO BOC-342 PK-H6 RAYMOND G. PREECE GREG KATNIK ZK-07 PK-H7 JORGE E. RIVERA PK-H7 1 DATE: 1999-07-02 15.25.06 S0007VL5 SHUTTLE COUNTDOWN - (LPS) DISTRIBUTION F - FINAL RAY W. NUSS FERDINAND JONES EV4 AC-58 JOHNSON SPACE CENTER BOEING NORTH AMERICAN HOUSTON, TX 77058 6633 CANOGA AVE ROBERT B. LUECKING CANOGA PARK, CA 91304 ZK-86 CALVIN J. CULBERTSON.....2 MATTHEW J. HOFMANN FC-51 ROC-LSS CCAS, FL 32899 JIM ALLAMON LISA A. MALONE ZK-21 PA-MSB CANDICE F. NORMAN.....................2 BRUCE D. BOUTON BOC-349 8A-44 TOM HILL BOEING DEFENSE & SPACE G ASC/ERD-FL P.O. BOX 3999 TAB CHOATE SEATTLE, WA 98124-2499 SA21 K. GRANT BOEING - ROCKETDYNE DIVI USH-440X MARSHALL SPACE FLIGHT CE UNITED SPACE ALLIANCE BLDG 4202, RM 405 600 GEMINI HUNTSVILLE, AL 35812 HOUSTON, TX 77058 AL SOFGE JERRY L. GREENWOOD EC 3731 TONY IPPOLITO MICHOUD ASSY FACILITY MILA LOCKHEED MARTIN NEAL E. VANSCYOC P.O. BOX 29304 F224 NEW ORLEANS, LA 70189 JAMES B. PARKS ALEX RODRIGUEZ.......3 PK-J-B ZK-86 PHIL LINTEREUR........................2 DEBBIE HAHN F264 NN-M2 RONALD L. ECKER MEGAN MISCHKOT BOC-327 N/A PETE WILSON MICHOUD ASSEMBLY FACILIT ZK-07 P.O. BOX 29300 JAMES REED NEW ORLEANS, LA 70189 EY-C DEPT 4250 WHIT BARTLETT PK-D2